Objectives: Operative time, previously identified as a risk factor for postoperative morbidity, is examined in patients undergoing benign cranial nerve tumor resection.
Design/setting/participants: This retrospective cohort analysis included patients enrolled in the ACS-NSQIP registry from 2007 through 2013 with a diagnosis of a benign cranial nerve neoplasm.
Main Outcome Measures: Primary outcomes included postoperative morbidity and mortality. Readmission and reoperation served as secondary outcomes.
Results: A total of 565 patients were identified. Mean (median) operative time was 398 (370) minutes. The 30-day complication, readmission, and return to the operating room rates were 9.9%, 9.9%, and 7.3%, respectively, on unadjusted analyses. CSF leak requiring reoperation or readmission occurred at a rate of 3.1%. On multivariable regression analysis, operations greater than 413 minutes were associated with an increased odds of overall complication (OR 4.26, 95% CI 2.08-8.72), return to the operating room (OR 2.65, 95% CI 1.23-5.67), and increased length of stay(1.6 days, 95% CI 0.94-2.23 days). Each additional minute of operative time was associated with an increased odds of overall complication (OR 1.004, 95% CI 1.002-1.006) and increased length of stay (0.006 days, 95% CI 0.004-0.008).
Conclusion: Increased operative time in patients undergoing surgical resection of a benign cranial nerve neoplasm was associated with an increased rate of complications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4949053 | PMC |
http://dx.doi.org/10.1055/s-0036-1572508 | DOI Listing |
Sci Rep
January 2025
Division of Dentistry, School of Medical Sciences, The University of Manchester, Manchester, M13 9PL, UK.
This study aims to evaluate the effects of the home bleaching method on the surface microhardness and surface roughness of both polished and unpolished CAD-CAM resin composite materials. A polymer-infiltrated ceramic network (PICN) block, Enamic (VE), along with four resin composite blocks (RCB) (Grandio [GN], Lava™ Ultimate [LV], BRILLIANT Crios [B], and Cerasmart [CS]), were prepared to dimensions of 14 mm × 12 mm × 2 mm and were categorized into unpolished and polished groups (n = 4). Microhardness measurements were conducted using a Vickers microhardness tester (300 gf load for 20 s) at various time points: before home bleaching, after home bleaching with 15% Opalescence for 8 h and for 56 h, 24 h after bleaching, and one month after bleaching.
View Article and Find Full Text PDFMicrosurgery
January 2025
Plastic, Reconstructive, and Aesthetic Surgery Unit, Nantes University Hospital, Nantes, France.
Introduction: Reconstructing large bone defects for lower limb salvage in the pediatric population remains challenging due to complex oncological or septic issues, limited surgical options, and lengthy procedures prone to complications. The vascularized double-barreled fibula free flap is pivotal for reconstructing large bones. In this article, we report our experience with this technique in the surgical management of pediatric tibial bone defects.
View Article and Find Full Text PDFJ Minim Invasive Gynecol
January 2025
Department of Obstetrics and Gynecology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea. Electronic address:
Study Subject: To investigate the impact of preoperative hormonal medication, including combined oral contraceptives (COCs) or dienogest, on operative findings in ovarian endometrioma surgery.
Design: A single-center, retrospective study.
Setting: Department of Gynecology, Samsung Medical Center, Republic of Korea.
J Stomatol Oral Maxillofac Surg
January 2025
Department of Prosthodontics and Gerostomatology, Poznan University of Medical Sciences, 60-792 Poznan, Poland.
Background: Tooth agenesis, particularly the absence of upper lateral incisors, presents substantial challenges for clinicians due to the associated bone atrophy, which limits the use of traditional implant solutions. Current options, such as endosseous implants combined with guided bone regeneration (GBR), often fail due to insufficient osseointegration in atrophic bone. This study aims to evaluate the effectiveness of custom-made, additively manufactured subperiosteal implants in addressing these challenges METHODS: This retrospective study assessed 16 custom-made subperiosteal implants used in 12 patients (10 females, 2 males; mean age 25 ± 2.
View Article and Find Full Text PDFInt J Cardiol
January 2025
Department of Cardiology, Cardiovascular Institute, Thorax Center, Erasmus MC, Rotterdam, the Netherlands; European Reference Network for Rare, Low Prevalence and Complex Diseases of the Heart (ERN GUARD-Heart), Amsterdam, the Netherlands.
Background: Little is known about the very long-term outcome in Tetralogy of Fallot (ToF) patients.
Objectives: To prospectively evaluate clinical outcome and quality-of-life after surgical repair of ToF.
Methods: Single-centre, longitudinal cohort-study evaluating every decade 144 ToF patients who underwent surgical repair <15 years of age between 1968 and 1980.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!