Correcting for Visuo-Haptic Biases in 3D Haptic Guidance.

PLoS One

MOVE Research Institute Amsterdam, Department of Human Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.

Published: July 2017

Visuo-haptic biases are observed when bringing your unseen hand to a visual target. The biases are different between, but consistent within participants. We investigated the usefulness of adjusting haptic guidance to these user-specific biases in aligning haptic and visual perception. By adjusting haptic guidance according to the biases, we aimed to reduce the conflict between the modalities. We first measured the biases using an adaptive procedure. Next, we measured performance in a pointing task using three conditions: 1) visual images that were adjusted to user-specific biases, without haptic guidance, 2) veridical visual images combined with haptic guidance, and 3) shifted visual images combined with haptic guidance. Adding haptic guidance increased precision. Combining haptic guidance with user-specific visual information yielded the highest accuracy and the lowest level of conflict with the guidance at the end point. These results show the potential of correcting for user-specific perceptual biases when designing haptic guidance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4954687PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0158709PLOS

Publication Analysis

Top Keywords

haptic guidance
36
visual images
12
haptic
10
guidance
10
biases
8
visuo-haptic biases
8
biases haptic
8
adjusting haptic
8
guidance user-specific
8
user-specific biases
8

Similar Publications

Background: Percutaneous image-guided cementoplasty is a medical procedure for strengthening bones structurally altered by disease, such as osteolytic metastasis. This procedure involves injecting biocompatible liquid bone cement, through one or more trocars into the damaged bone. Within a few minutes the bone cement hardens and restores the rigidity of the bony structure.

View Article and Find Full Text PDF

Haptic-Based Real-Time Platform for Microswarm Steering in a Multi-Bifurcation Vascular Network.

Nanomaterials (Basel)

November 2024

School of Computer Science and Electronic Engineering, University of Essex, Colchester CO4 3SQ, UK.

The use of electromagnetic fields to control a collection of magnetic nanoparticles, known as a microswarm, has many promising applications. Current research often makes use of accurate but time-consuming simulations lacking real-time human input. On the contrary, human interaction is possible with a real-time simulator, allowing the collection of valuable user interaction data.

View Article and Find Full Text PDF

Vehicle drivability, defined as the smooth operation and stability of a vehicle in response to driver inputs, significantly influences the performance of passenger cars. Among various driving conditions, tip-in acceleration is one of the most frequently encountered and crucial factors affecting drivability. This study investigates preferred longitudinal acceleration profiles for electric vehicles through subjective evaluations obtained from on-road tests.

View Article and Find Full Text PDF
Article Synopsis
  • * A new shape-changing haptic interface (Shape) was tested, showing that individuals with VI were able to locate virtual targets much faster and more efficiently using Shape compared to traditional vibration feedback.
  • * Shape received better user experience ratings than vibration feedback, and its performance matched that of natural vision, indicating potential for this technology in enhancing navigation for those with VI.
View Article and Find Full Text PDF

MINARO DRS: usability study of a robotic-assisted laminectomy.

Int J Comput Assist Radiol Surg

November 2024

Chair of Medical Engineering, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstraße 20, 52074, Aachen, Germany.

Purpose: Although the literature shows that robotic assistance can support the surgeon, robotic systems are not widely spread in clinics. They often incorporate large robotic arms adopted from the manufacturing industry, imposing safety hazards when in contact with the patient or surgical staff. We approached this limitation with a modular dual robot consisting of an ultra-lightweight carrier robot for rough prepositioning and small, highly dynamic, application-specific, interchangeable tooling robots.

View Article and Find Full Text PDF