A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Calculating Partition Coefficients of Small Molecules in Octanol/Water and Cyclohexane/Water. | LitMetric

Calculating Partition Coefficients of Small Molecules in Octanol/Water and Cyclohexane/Water.

J Chem Theory Comput

Department of Chemistry and ‡Department of Pharmaceutical Sciences, University of California, Irvine, California 92697, United States.

Published: August 2016

Partition coefficients describe how a solute is distributed between two immiscible solvents. They are used in drug design as a measure of a solute's hydrophobicity and a proxy for its membrane permeability. We calculate partition coefficients from transfer free energies using molecular dynamics simulations in explicit solvent. Setup is done by our new Solvation Toolkit which automates the process of creating input files for any combination of solutes and solvents for many popular molecular dynamics software packages. We calculate partition coefficients between octanol/water and cyclohexane/water with the Generalized AMBER Force Field (GAFF) and the Dielectric Corrected GAFF (GAFF-DC). With similar methods in the past we found a root-mean-squared error (RMSE) of 6.3 kJ/mol in hydration free energies which would correspond to an error of around 1.6 log units in partition coefficients if solvation free energies in both solvents were estimated with comparable accuracy. Here we find an overall RMSE of about 1.2 log units with both force fields. Results from GAFF and GAFF-DC seem to exhibit systematic biases in opposite directions for calculated cyclohexane/water partition coefficients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5053177PMC
http://dx.doi.org/10.1021/acs.jctc.6b00449DOI Listing

Publication Analysis

Top Keywords

partition coefficients
24
free energies
12
octanol/water cyclohexane/water
8
cyclohexane/water partition
8
calculate partition
8
molecular dynamics
8
gaff gaff-dc
8
log units
8
coefficients
6
partition
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!