A retrospective study (1983-1984) of magnetic resonance imaging (MRI) and computed tomography (CT) examinations in 471 patients with known pathology in the brain and craniocervical junction was conducted in order to determine the relative efficacy of MRI versus CT. All MRI examinations involved slice thickness greater than 10 mm, and only single-slice single-echo or multislice single-echo imaging techniques were available. These studies were evaluated independently by two neuroradiologists from a panel of six for anatomic abnormalities, lesion contrast, and radiologist's impression. Results, which excluded microadenomas of the pituitary and approximately 9% of studies in which consensus was not achieved by the readers, were as follows: (1) 14% of the studies were positive on MRI but normal on CT; (2) in 55% of the studies, MRI was better than CT; (3) MRI was equal or better than CT in 95% of the studies; and (4) CT was better than MRI in 5% (21/421) of the examinations. There were no patients in this series where CT was positive but MRI missed the abnormality.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0899-7071(89)90120-4DOI Listing

Publication Analysis

Top Keywords

computed tomography
8
magnetic resonance
8
resonance imaging
8
mri
8
positive mri
8
better mri
8
studies
5
tomography versus
4
versus magnetic
4
imaging brain
4

Similar Publications

Background: Previous studies utilizing dual-energy CT (DECT) for evaluating treatment efficacy in nasopharyngeal cancinoma (NPC) are limited. This study aimed to investigate whether the parameters from DECT can predict the response to induction chemotherapy in NPC patients in two centers.

Methods: This two-center retrospective study included patients diagnosed with NPC who underwent contrast-enhanced DECT between March 2019 and November 2023.

View Article and Find Full Text PDF

Background: Cemento-osseous dysplasia (COD) is the most common apical radiopaque lesion that develops in the tooth-bearing area. However, large, destructive lesions are rare. Herein, we report a case in which COD extended to bilateral condyles, affecting the entire mandible, and was managed with denosumab rather than surgical resection.

View Article and Find Full Text PDF

In case of venous route abnormality during a leadless pacemaker (LP) implantation, it can be challenging if we still performed via the predesigned femoral vein. We report a patient with normal preoperative laboratory and image results, but azygos continuation of the inferior vena cava (IVC) was suspected during the procedure. Then, we decided to change the implantation strategy, the LP implantation was successfully performed via right jugular vein instead of the classical IVC route.

View Article and Find Full Text PDF

Purpose: To evaluate the staging performance of positron emission tomography/magnetic resonance imaging (PET/MRI) for confirmed esophageal cancer based on the TNM classification system as well as compare it to other alternative modalities (e.g., endoscopic ultrasonography (EUS), computed tomography (CT), MRI, and PET/CT) in a full head-to-head manner.

View Article and Find Full Text PDF

To develop and validate non-contrast computed tomography (NCCT)-based radiomics method combines machine learning (ML) to investigate invisible microscopic acute ischaemic stroke (AIS) lesions. We retrospectively analyzed 1122 patients from August 2015 to July 2022, whose were later confirmed AIS by diffusion-weighted imaging (DWI). However, receiving a negative result was reported by radiologists according to the NCCT images.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!