A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Remote-controlled delivery of CO via photoactive CO-releasing materials on a fiber optical device. | LitMetric

Remote-controlled delivery of CO via photoactive CO-releasing materials on a fiber optical device.

Dalton Trans

Institute for Inorganic and Analytical Chemistry (IAAC), Friedrich Schiller University Jena, Humboldtstr. 8, D-07743 Jena, Germany. and Jena Center for Soft Matter (JCSM), Friedrich Schiller University Jena, Philosophenweg 7, D-07743 Jena, Germany.

Published: August 2016

Although carbon monoxide (CO) delivery materials (CORMAs) have been generated, remote-controlled delivery with light-activated CORMAs at a local site has not been achieved. In this work, a fiber optic-based CO delivery system is described in which the photoactive and water insoluble CO releasing molecule (CORM) manganese(i) tricarbonyl [(OC)3Mn(μ3-SR)]4 (R = nPr, 1) has been non-covalently embedded into poly(l-lactide-co-d/l-lactide) and poly(methyl methacrylate) non-woven fabrics via the electrospinning technique. SEM images of the hybrid materials show a porous fiber morphology for both polymer supports. The polylactide non-woven fabric was attached to a fiber optical device. In combination with a laser irradiation source, remote-controlled and light-triggered CO release at 405 nm excitation wavelength was achieved. The device enabled a high flexibility of the spatially and timely defined application of CO with the biocompatible hybrid fabric in aqueous media. The rates of liberated CO were adjusted with the light intensity of the laser. CO release was confirmed via ATR-IR spectroscopy, a portable electrochemical CO sensor and a heterogeneous myoglobin assay.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c6dt02011aDOI Listing

Publication Analysis

Top Keywords

remote-controlled delivery
8
fiber optical
8
optical device
8
delivery photoactive
4
photoactive co-releasing
4
co-releasing materials
4
fiber
4
materials fiber
4
device carbon
4
carbon monoxide
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!