Formation of a nanometer-wide gap between tip and substrate electrodes by scanning electrochemical microscopy (SECM) enables voltammetric measurement of ultrafast electron-transfer kinetics. Herein, we demonstrate the advantage of SECM-based nanogap voltammetry to assess the cleanness of the substrate surface in solution by confirming that airborne contamination of highly oriented pyrolytic graphite (HOPG) causes the nonideal asymmetry of paired nanogap voltammograms of (ferrocenylmethyl)trimethylammonium (Fc(+)). We hypothesize that the amperometric response of a 1 μm-diameter Pt tip is less enhanced in the feedback mode, where more hydrophilic Fc(2+) is generated from Fc(+) at the tip and reduced voltammetrically at the HOPG surface covered with airborne hydrophobic contaminants. The tip current is more enhanced in the substrate generation/tip collection mode, where less charged Fc(+) is oxidized at the contaminated HOPG surface. In fact, symmetric pairs of nanogap voltammograms are obtained with the cleaner HOPG surface that is exfoliated in humidified air and covered with a nanometer-thick water adlayer to suppress airborne contamination. This result disproves a misconception that the asymmetry of paired nanogap voltammograms is due to electron exchange mediated by Fc(2+) adsorbed on the glass sheath of the tip. Moreover, weak Fc(+) adsorption on the HOPG surface causes only the small hysteresis of each voltammogram upon forward and reverse sweeps of the HOPG potential. Significantly, no Fc(2+) adsorption on the HOPG surface ensures that the simple outer-sphere pathway mediates ultrafast electron transfer of the Fc(2+/+) couple with standard rate constants of ≥12 cm/s as estimated from symmetric pairs of reversible nanogap voltammograms.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.6b02273DOI Listing

Publication Analysis

Top Keywords

nanogap voltammograms
20
hopg surface
20
asymmetry paired
12
paired nanogap
12
scanning electrochemical
8
electrochemical microscopy
8
airborne contamination
8
symmetric pairs
8
adsorption hopg
8
hopg
7

Similar Publications

Here, we demonstrate for the first time that the mechanism of adsorption-coupled electron-transfer (ACET) reactions can be identified experimentally. The electron transfer (ET) and specific adsorption of redox-active molecules are coupled in many electrode reactions with practical importance and fundamental interest. ACET reactions are often represented by a concerted mechanism.

View Article and Find Full Text PDF

Electrochemical measurements with unprecedentedly high sensitivity, selectivity, and kinetic resolution have been enabled by a pair of electrodes separated by a nanometer-wide gap. The fabrication of nanogap electrodes, however, requires extensive nanolithography or nanoscale electrode positioning, thereby preventing the full exploration of this powerful method in electrode design and application. Herein, we report the simple fabrication of double-carbon-fiber ultramicroelectrodes (UMEs) with nanometer-wide gaps not only to facilitate nanogap-based electrochemical measurements but also to gain high time resolution, signal-to-background ratio, and kinetic selectivity for dopamine against ascorbic acid.

View Article and Find Full Text PDF

Diffuse Layer Effect on Electron-Transfer Kinetics Measured by Scanning Electrochemical Microscopy (SECM).

J Phys Chem Lett

April 2017

Department of Chemistry and Biochemistry, Queens College, Flushing, New York 11367, United States.

Recent theoretical and experimental studies revealed strong effects of the electrical double layer (EDL) on mass transfer at nanometer-sized electrodes and in electrochemical nanogaps. Although the EDL effect is much stronger in weakly supported media, it can significantly influence the kinetics of electron-transfer processes involving multicharged ionic redox species, even at high concentrations of supporting electrolyte. We measured the kinetics of Fe(CN) oxidation in 1 M KCl solution at the Pt nanoelectrode used as a tip in the scanning electrochemical microscope.

View Article and Find Full Text PDF

Toward More Reliable Measurements of Electron-Transfer Kinetics at Nanoelectrodes: Next Approximation.

Anal Chem

December 2016

Department of Chemistry and Biochemistry, Queens College-CUNY, Flushing, New York 11367, United States.

Steady-state voltammetry at nanoelectrodes and scanning electrochemical microscopy (SECM) have recently been used to measure kinetics of several rapid heterogeneous electron transfer (ET) reactions. One problem with those experiments was that the dependence of the shape of the steady-state voltammogram on kinetic parameters becomes weak when the reaction rate approaches the diffusion limit. The possibility to fit the same experimental voltammogram using different combinations of the standard rate constant, transfer coefficient, and standard potential results in significant uncertainties in extracted parameter values.

View Article and Find Full Text PDF

Scanning Electrochemical Microscopy of Carbon Nanomaterials and Graphite.

Acc Chem Res

September 2016

Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States.

Carbon materials are tremendously important as electrode materials in both fundamental and applied electrochemistry. Recently, significant attention has been given not only to traditional carbon materials, but also to carbon nanomaterials for various electrochemical applications in energy conversion and storage as well as sensing. Importantly, many of these applications require fast electron-transfer (ET) reactions between a carbon surface and a redox-active molecule in solution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!