Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: The aim of this study was to evaluate the impact of increased aortic angulation (AA) on acute procedural success following transcatheter aortic valve replacement (TAVR).
Background: The degree of angulation between the aorta and the heart can make accurate positioning of the bioprosthesis during TAVR more demanding, particularly in instances of an extremely angulated or horizontal aortic root. Nonetheless, there are limited data on the impact of AA on the acute success of TAVR.
Methods: We assessed 582 patients who underwent TAVR at our institute and had contrast computed tomography available for AA evaluation. TAVR endpoints, device success, and adverse events were considered according to the Valve Academic Research Consortium-2 definitions.
Results: The mean angulation of the aorta was 47.3 ± 8.7°. Patients were therefore divided into 2 groups: AA <48° and AA ≥48°. AA in the 480 patients who underwent balloon-expandable (BE) TAVR did not influence acute procedural success or short-term clinical outcome. In contrast, increased AA among the 102 patients who underwent self-expandable (SE) TAVR was found to significantly attenuate procedural success (area under the curve: 0.73; 95% confidence interval: 0.61 to 0.85; p = 0.008). The numerical cutoff for AA with the highest sum of sensitivity and specificity for device success was ≥48° (sensitivity 85%, specificity 61%). Moreover, patients whose AA was ≥48° were also associated with an increased need for a second valve and post-dilation, had increased fluoroscopy time and increased valve embolization, and had increased post-procedural paravalvular regurgitation greater than or equal to mild following SE TAVR. Major complications at 30 days, including mortality were similar between AA groups. Six-month mortality was also similar between both AA groups.
Conclusions: Increased aortic root angulation adversely influences acute procedural success following SE but not BE TAVR. Because of these data, BE valves may be preferred when evaluating patients with high AA before TAVR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcmg.2016.02.030 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!