Purpose: To evaluate the relationship between functional parameters of repeated flicker-defined form perimetry (FDF) and structural parameters of spectral-domain optical coherence tomography (SD-OCT) in glaucoma suspects with normal findings in achromatic standard automated perimetry (SAP).

Methods: Patients with optic nerve heads (ONH) clinically suspicious for glaucoma and normal SAP findings were enrolled in this prospective study. Each participant underwent visual field (VF) testing with FDF perimetry, using the Heidelberg Edge Perimeter (HEP, Heidelberg Engineering, Heidelberg, Germany) at two consecutive visits. Peripapillary RNFL thickness was obtained by SD-OCT (Spectralis, Heidelberg Engineering, Heidelberg, Germany). Correlations and regression analyses of global and sectoral peripapillary RNFL thickness with corresponding global and regional VF sensitivities were investigated.

Results: A consecutive series of 65 study eyes of 36 patients were prospectively included. The second FDF test (HEP II) was used for analysis. Cluster-point based suspicious VF defects were found in 34 eyes (52%). Significant correlations were observed between mean global MD (PSD) of HEP II and SD-OCT-based global peripapillary RNFL thickness (r = 0.380, p = 0.003 for MD and r = -0.516, p < 0.001 for PSD) and RNFL classification scores (R = 0.157, p = 0.002 for MD and R = 0.172, p = 0.001 for PSD). Correlations between mean global MD and PSD of HEP II and sectoral peripapillary RNFL thickness and classification scores showed highest correlations between function and structure for the temporal superior and temporal inferior sectors whereas sectoral MD and PSD correlated weaker with sectoral RNFL thickness. Correlations between linear RNFL values and untransformed logarithmic MD values for each segment were less significant than correlations between logarithmic MD values and RNFL thickness.

Conclusions: In glaucoma suspects with normal SAP, global and sectoral peripapillary RNFL thickness is correlated with sensitivity and VF defects in FDF perimetry.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02713683.2016.1190848DOI Listing

Publication Analysis

Top Keywords

rnfl thickness
24
peripapillary rnfl
20
glaucoma suspects
12
sectoral peripapillary
12
rnfl
9
flicker-defined form
8
form perimetry
8
spectral-domain optical
8
optical coherence
8
coherence tomography
8

Similar Publications

Objective: To evaluate the effects of Fanconi anemia (FA) on retinal and choroidal microvasculature using Optical Coherence Tomography (OCT) and Optical Coherence Tomography Angiography (OCTA).

Design: Cohort study with age-matched controls.

Subjects And Participants: This study included 11 eyes from 11 patients diagnosed with FA and 12 eyes from 12 age-matched healthy controls.

View Article and Find Full Text PDF

Precis: Current optical coherence tomography normative sample data may not represent diverse human optic nerve anatomy to accurately classify all individuals with true glaucomatous optic neuropathy.

Purpose: To compare optic nerve head (ONH) measurements between published values from an optical coherence tomography (OCT) normative database and a more diverse cohort of healthy individuals.

Patients And Methods: ONH parameters from healthy participants of the Michigan Screening and Intervention for Glaucoma and Eye Health through Telemedicine (MI-SIGHT) program and the Topcon Maestro-1 normative cohort were compared.

View Article and Find Full Text PDF

Prcis: Cognitive impairment in multiple domains was observed in primary open angle glaucoma patients as compared to age and gender matched healthy controls.

Objective: Evaluation of cognitive impairment in individuals with Primary Open Angle Glaucoma (POAG).

Methods: In this case-control study, individuals with POAG (cases, n=70) were compared with age- and sex-matched healthy individuals (controls, n=70) using detailed ophthalmological evaluation, cognitive assessment and serum cortisol level.

View Article and Find Full Text PDF

Prcis: The discriminant function of glaucoma, obtained by the Laguna ONhE colorimetric program, significantly correlates with the BMO-MRW. Furthermore, the diagnostic capacity was inferior to other structural tests in POAG patients.

Purpose: To evaluate the diagnostic capability for glaucoma and the correlation between peripapillary and macular parameters using spectral domain optical coherence tomography (SD-OCT) and optic nerve head hemoglobin (OHN Hb) levels assessed by the Laguna ONhE® software using colorimetric analysis.

View Article and Find Full Text PDF

Background: To compare structural and vascular parameters between advanced pseudoexfoliation glaucoma (PXG) and primary open-angle glaucoma (POAG).

Methods: One hundred and six eyes of 81 patients were enrolled in this cross-sectional study. All patients underwent complete ophthalmic examination and measurement of the thickness of the peripapillary retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!