A new pressure, volume, temperature, and, time (PVTt) primary gas flow standard at the National Institute of Standards and Technology has an expanded uncertainty (k = 2) of between 0.02 % and 0.05 %. The standard spans the flow range of 1 L/min to 2000 L/min using two collection tanks and two diverter valve systems. The standard measures flow by collecting gas in a tank of known volume during a measured time interval. We describe the significant and novel features of the standard and analyze its uncertainty. The gas collection tanks have a small diameter and are immersed in a uniform, stable, thermostatted water bath. The collected gas achieves thermal equilibrium rapidly and the uncertainty of the average gas temperature is only 7 mK (22 × 10(-6) T). A novel operating method leads to essentially zero mass change in and very low uncertainty contributions from the inventory volume. Gravimetric and volume expansion techniques were used to determine the tank and the inventory volumes. Gravimetric determinations of collection tank volume made with nitrogen and argon agree with a standard deviation of 16 × 10(-6) VT . The largest source of uncertainty in the flow measurement is drift of the pressure sensor over time, which contributes relative standard uncertainty of 60 × 10(-6) to the determinations of the volumes of the collection tanks and to the flow measurements. Throughout the range 3 L/min to 110 L/min, flows were measured independently using the 34 L and the 677 L collection systems, and the two systems agreed within a relative difference of 150 × 10(-6). Double diversions were used to evaluate the 677 L system over a range of 300 L/min to 1600 L/min, and the relative differences between single and double diversions were less than 75 × 10(-6).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4844527PMC
http://dx.doi.org/10.6028/jres.108.004DOI Listing

Publication Analysis

Top Keywords

collection tanks
12
gas flow
8
flow standard
8
range l/min
8
tank volume
8
double diversions
8
standard
7
gas
6
flow
6
uncertainty
6

Similar Publications

Background: Antibiotic use has undesirable side-effects on the host, including perturbations of gut microbiota, immunity, and health. Mammalian studies have demonstrated that concomitant/post antibiotic use of pro-, pre-, and synbiotics could re-establish gut microbiota and prevent detrimental host effects. However, studies evaluating similar effects in fish are scanty.

View Article and Find Full Text PDF

It is urgently desired to develop high-performance wind energy collectors to power numerous microelectronic devices along with the Internet of Things (IoT). A roller-type triboelectric nanogenerator (R-TENG) based on rotational friction between wool and stacked interfaces is proposed and efficiently used for harvesting wind energy. Wool, an electropositive and flexible material, is utilized in the design, effectively reducing abrasion on the contact surface and adjusting the output in response to varying compression levels.

View Article and Find Full Text PDF

One of the main causes of air pollution, particularly in large cities, is vehicles due to it continued use of hydrocarbon fuels. The understanding of nonlinear interactions of vehicle parameters uncovers more realistic relationships for enhancing formulation of strategies to address vehicle-related pollution. Thus, the study aims to evaluate the interaction and quadratic effect of vehicle parameters on Hydrocarbon (HC), Carbon dioxide (CO2), Carbon monoxide (CO), and Nitrogen oxide (NOx) emissions.

View Article and Find Full Text PDF

Following the increased mass mortality of populations in the Mediterranean, reliable protocols for the transport, maintenance, and controlled reproduction of this highly endangered species were drawn up within the European Life Pinna project. To test these protocols, the large Pinnidae , which shares similar habits to , has been used. In December 2022, a transport trial of nine specimens of from Trieste (NE Italy) to Camogli (NW Italy) was carried out.

View Article and Find Full Text PDF

Innovative Seatbelt-Integrated Metasurface Radar for Enhanced In-Car Healthcare Monitoring.

Sensors (Basel)

November 2024

SDU Health of Informatics, The Maersk Mc-Kinney Moller Institute, Faculty of Engineering, University of Southern Denmark, 5230 Odense M, Denmark.

This study introduces a novel seatbelt-integrated, non-invasive, beam-focusing metamaterial sensing system characterized by its thinness and flexibility. The system comprises a flexible transmitarray lens and an FMCW radar sensor, enabling the accurate detection and analysis of seatbelt usage and positioning through human tissue. The metasurface design remains effective even when subjected to different bending angles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!