A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Lens coupled tunable Young's double pinhole system for hard X-ray spatial coherence characterization. | LitMetric

AI Article Synopsis

  • A modified Young's double slit experiment was conducted using adjustable pinholes and a special lens to study the spatial coherence of hard X-rays.
  • The varying distance between the pinholes allowed for sensitive measurement across a range of experimental settings, while the lens facilitated a compact experimental setup compared to traditional methods.
  • Experimental tests at the ESRF ID06 beamline successfully measured spatial coherence and source size, aligning well with findings from other techniques.

Article Abstract

We have implemented a modified Young's double slit experiment using pinholes with tunable separation distance coupled with compound refractive lens for hard X-ray spatial coherence characterization. Varying distance between the apertures provides a high sensitivity to the determination of spatial coherence across a wide range of experimental parameters. The use of refractive lenses as a Fourier transformer ensures far field registration conditions and allows the realization of a very compact experimental setup in comparison with the classical Young technique and its derivatives. The tunable double aperture interferometer was experimentally tested at the ESRF ID06 beamline in the energy range from 8 to 25 keV. The spatial coherence and the source size were measured by evaluating the visibility of the interference fringes at various separation distances between the apertures and this value agrees very well with the data obtained by other techniques. The proposed scheme can be used for comprehensive characterization of the coherence properties of the source on low emittance synchrotrons in the hard X-ray region.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.24.013679DOI Listing

Publication Analysis

Top Keywords

spatial coherence
16
hard x-ray
12
young's double
8
x-ray spatial
8
coherence characterization
8
coherence
5
lens coupled
4
coupled tunable
4
tunable young's
4
double pinhole
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!