Underwater spectral imaging is a promising method for mapping, classification and health monitoring of coral reefs and seafloor inhabitants. However, the spectrum of light is distorted during the underwater imaging process due to wavelength-dependent attenuation by the water. This paper presents a model-based method that accurately restores brightness of underwater spectral images captured with narrowband filters. A model is built for narrowband underwater spectral imaging. The model structure is derived from physical principles, representing the absorption, scattering and refraction by water and the optical properties of narrowband filters, lenses and image sensors. The model coefficients are calibrated based on spectral images captured underwater and in air. With the imaging model available, energy loss due to water attenuation is restored for images captured at different underwater distances. An experimental setup is built and experiments are carried out to verify the proposed method. Underwater images captured within an underwater distance of 260 cm are restored and compared with those in air. Results show that the relative restoration error is 3.58% on average for the test images, thus proving the accuracy of the proposed method.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.24.013101DOI Listing

Publication Analysis

Top Keywords

images captured
20
underwater spectral
16
spectral images
12
narrowband filters
12
captured underwater
12
underwater
9
captured narrowband
8
spectral imaging
8
imaging model
8
proposed method
8

Similar Publications

Alcohol-based fuels have shown high compatibility with spark-ignition (SI) engines, which require improvements in fuel efficiency and emissions reduction to meet modern environmental standards. While extensive research has been conducted on ethanol and other lower-order alcohols, there has been comparatively limited investigation into higher-order alcohols like butanol and pentanol as fuel alternatives. Previous studies on pentanol-gasoline blends in SI engines have demonstrated improved engine performance and reduced emissions.

View Article and Find Full Text PDF

Mid-infrared photoacoustic microscopy can capture biochemical information without staining. However, the long mid-infrared optical wavelengths make the spatial resolution of photoacoustic microscopy significantly poorer than that of conventional confocal fluorescence microscopy. Here, we demonstrate an explainable deep learning-based unsupervised inter-domain transformation of low-resolution unlabeled mid-infrared photoacoustic microscopy images into confocal-like virtually fluorescence-stained high-resolution images.

View Article and Find Full Text PDF

For finely representation of complex reservoir units, higher computing overburden and lower spatial resolution are limited to traditional stochastic simulation. Therefore, based on Generative Adversarial Networks (GANs), spatial distribution patterns of regional variables can be reproduced through high-order statistical fitting. However, parameters of GANs cannot be optimized under insufficient training samples.

View Article and Find Full Text PDF

Reconfiguration of brain network dynamics in bipolar disorder: a hidden Markov model approach.

Transl Psychiatry

December 2024

School of Computer Science and Technology (School of Data Science), Taiyuan University of Technology, Taiyuan, 030024, China.

Bipolar disorder (BD) is a neuropsychiatric disorder characterized by severe disturbance and fluctuation in mood. Dynamic functional connectivity (dFC) has the potential to more accurately capture the evolving processes of emotion and cognition in BD. Nevertheless, prior investigations of dFC typically centered on larger time scales, limiting the sensitivity to transient changes.

View Article and Find Full Text PDF

The pulmonary valve (PV), although often less emphasized than other heart valves, is crucial for cardiac function and hemodynamics. Historically, the PV has been underrepresented in echocardiographic assessments due to its rare involvement in pathological conditions, particularly in adults. Additionally, the anatomical position of the PV makes it one of the most challenging valves to visualize using conventional echocardiography.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!