Systematic errors induced by distortions in the pump pulse of conventional Brillouin distributed fiber sensors are thoroughly investigated. Experimental results, supported by a theoretical analysis, demonstrate that the two probe sidebands in standard Brillouin optical time-domain analyzers provide a non-zero net gain on the pump pulse, inducing severe distortions of the pump when scanning the pump-probe frequency offset, especially at high probe power levels. Compared to the impact of non-local effects reported in the state-of-the-art, measurements here indicate that for probe powers in the mW range (below the onset of amplified spontaneous Brillouin scattering), the obtained gain and loss spectra show two strong side-lobes that lead to significant strain/temperature errors. This phenomenon is not related to the well-known spectral hole burning resulting from pump depletion, but it is strictly related to the temporal and spectral distortions that the pump pulse experiences when scanning the Brillouin gain/loss spectrum. As a solution to this problem, a novel scanning scheme for Brillouin sensing is proposed. The method relies on a fixed frequency separation between the two probe sidebands, so that a flat zero net gain is achieved on the pump pulse when scanning the pump-probe frequency offset. The proposed technique is experimentally validated, demonstrating its ability to completely cancel out non-local effects up to a probe power ultimately limited by the onset of amplified spontaneous Brillouin scattering. The method allows for one order of magnitude improvement in the figure-of-merit of optimized long-range Brillouin distributed fiber sensors, enabling measurements along a 100 km-long sensing fiber with 2 m spatial resolution and with no need of added features for performance enhancement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.24.010188 | DOI Listing |
Cardiovasc Eng Technol
January 2025
Institute for Medical Engineering and Science, Massachusetts Institute of Technology, MA, Cambridge, USA.
Purpose: Atrial fibrillation (AF) is the most common chronic cardiac arrhythmia that increases the risk of stroke, primarily due to thrombus formation in the left atrial appendage (LAA). Left atrial appendage occlusion (LAAO) devices offer an alternative to oral anticoagulation for stroke prevention. However, the complex and variable anatomy of the LAA presents significant challenges to device design and deployment.
View Article and Find Full Text PDFHeart Vessels
January 2025
Saitama Sekishinkai Hospital, 2-37-20 Irumagawa, Sayama, Saitama, Japan.
Postinfarction ventricular septal rupture (PIVSR) is a rare but serious complication of acute myocardial infarction. Determining how to conduct surgical repair safely is critical. We compared the outcomes of Impella and intra-aortic balloon pump (IABP) implantation during perioperative mechanical circulatory support management in patients with PIVSR (n = 22).
View Article and Find Full Text PDFSci Rep
January 2025
Department of Physics and Astronomy, Aarhus University, Aarhus, Denmark.
Roaming reactions involving a neutral fragment of a molecule that transiently wanders around another fragment before forming a new bond are intriguing and peculiar pathways for molecular rearrangement. Such reactions can occur for example upon double ionization of small organic molecules, and have recently sparked much scientific interest. We have studied the dynamics of the [Formula: see text]-roaming reaction leading to the formation of [Formula: see text] after two-photon double ionization of ethanol and 2-aminoethanol, using an XUV-UV pump-probe scheme.
View Article and Find Full Text PDFFoods
January 2025
MOST-USDA Joint Research Center for Food Safety, School of Agriculture and Biology and State Key Laboratory of Microbial Metabolism, Shanghai Jiao Tong University, Shanghai 200240, China.
is a major cause of foodborne illness worldwide, and the emergence of ciprofloxacin-resistant strains poses a significant threat to food safety and public health. This study aimed to investigate the prevalence, spread, and mechanisms of ciprofloxacin resistance in isolates from food and patient samples in Shanghai, China. A total of 1625 isolates were screened, and 34 (2.
View Article and Find Full Text PDFProc Natl Acad Sci U S A
January 2025
Faculty of Technical Chemistry, Institute of Chemical Technologies and Analytics, Technische Universität Wien, Vienna 1060, Austria.
Atomic force microscopy-infrared spectroscopy (AFM-IR) is a photothermal scanning probe technique that combines nanoscale spatial resolution with the chemical analysis capability of mid-infrared spectroscopy. Using this hybrid technique, chemical identification down to the single molecule level has been demonstrated. However, the mechanism at the heart of AFM-IR, the transduction of local photothermal heating to cantilever deflection, is still not fully understood.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!