In this paper, the performance of an end-pumped laser amplifier was experimentally studied by adjusting the pumping wavelength of a laser diode. An interesting phenomenon was observed: that the gain would decrease with an increase in absorbed pump power. The scaled output power of 0.3 at. % doped 20 mm long Nd:YVO crystal decreased from 0.48 to 0.2 W when the absorbed pump power increased from 17.5 to 17.8 W. Theoretical analysis was demonstrated according to our previous model. The long crystal length is the main reason for the observed phenomenon. This phenomenon could be utilized to enhance amplifier gain and improve thermal performance, including the maximal temperature and thermal stress of the crystal.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.55.004946DOI Listing

Publication Analysis

Top Keywords

adjusting pumping
8
pumping wavelength
8
absorbed pump
8
pump power
8
gain change
4
change adjusting
4
wavelength end-pumped
4
end-pumped ndyvo
4
ndyvo amplifier
4
amplifier paper
4

Similar Publications

The Heisenberg-RIXS instrument at the European XFEL.

J Synchrotron Radiat

January 2025

Institute Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Albert-Einstein-Straße 15, 12489 Berlin, Germany.

Resonant inelastic X-ray scattering (RIXS) is an ideal X-ray spectroscopy method to push the combination of energy and time resolutions to the Fourier transform ultimate limit, because it is unaffected by the core-hole lifetime energy broadening. Also, in pump-probe experiments the interaction time is made very short by the same core-hole lifetime. RIXS is very photon hungry so it takes great advantage from high-repetition-rate pulsed X-ray sources like the European XFEL.

View Article and Find Full Text PDF

Tumor organoids are biological models for studying precision medicine. Microfluidic technology offers significant benefits for high throughput drug screening using tumor organoids. However, the range of concentrations achievable with traditional linear gradient generators in microfluidics is restricted, generating logarithmic drug concentration gradients by adjusting the channel ratio in the chip is confined to single-drug dilution chips, significantly restricting the application of microfluidics in drug screening.

View Article and Find Full Text PDF

Introduction Monitored anesthesia care (MAC) is an anesthesia management method in which anesthesiologists use the minimum necessary intravenous anesthetics to achieve sedation and pain relief while maintaining spontaneous breathing. The challenge for the anesthesiologist is to find the correct balance between inhibiting the patient's stress response to invasive treatment, maintaining intraoperative hemodynamic stability, and doing so as quickly as possible. We hypothesized that diluting remifentanil (D-remi) to 10 μg/mL and increasing the rate of administration would increase the responsiveness of the syringe pump and allow for better control of anesthetic depth.

View Article and Find Full Text PDF
Article Synopsis
  • Fiber mode-locked lasers produce ultrashort pulses and can have varying optical outputs based on cavity adjustments, leading to challenges due to their multistability.
  • The study showcases the use of the Soft Actor-Critic algorithm to generate a harmonic mode-locked regime in a fiber laser, utilizing an ion-gated nanotube saturable absorber.
  • This research presents a machine-learning approach to effectively manage pumping power and absorber transmission, enabling automatic adjustments to overcome the complexities of nonlinear optical systems.
View Article and Find Full Text PDF

Maintaining precise intragastric pressure during gastrointestinal endoscopy is critical for patient safety and diagnostic accuracy, yet current methods relying on manual adjustments pose risks of improper insufflation. This study aimed to develop an automated gastric pressure control system for flexible endoscopy, addressing these challenges with a piezoresistive pressure sensor that can be integrated into a 7.3 mm diameter flexible endoscope.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!