Validation of Computed Tomography-based Attenuation Correction of Deviation between Theoretical and Actual Values in Four Computed Tomography Scanners.

Asia Ocean J Nucl Med Biol

Biological Systems Sciences Program, Graduate School of Comprehensive Scientific Research, Prefectural University of Hiroshima, Hiroshima, Japan.

Published: July 2016

Objectives: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC), using the bilinear scaling method.

Methods: The measured attenuation coefficient (μm) was compared to the theoretical attenuation coefficient (μt), using four different CT scanners and an RMI 467 phantom. The effective energy of CT beam X-rays was calculated, using the aluminum half-value layer method and was used in conjunction with an attenuation coefficient map to convert the CT numbers to μm values for the photon energy of 140 keV. We measured the CT number of RMI 467 phantom for each of the four scanners and compared the μm and μt values for the effective energies of CT beam X-rays, effective atomic numbers, and physical densities.

Results: The μm values for CT beam X-rays with low effective energies decreased in high construction elements, compared with CT beam X-rays of high effective energies. As the physical density increased, the μm values elevated linearly. Compared with other scanners, the μm values obtained from the scanner with CT beam X-rays of maximal effective energy increased once the effective atomic number exceeded 10.00. The μm value of soft tissue was equivalent to the μt value. However, the ratios of maximal difference between μm and μt values were 25.4% (lung tissue) and 21.5% (bone tissue), respectively. Additionally, the maximal difference in μm values was 6.0% in the bone tissue for each scanner.

Conclusion: The bilinear scaling method could accurately convert CT numbers to μ values in soft tissues.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4938878PMC
http://dx.doi.org/10.7508/aojnmb.2016.02.004DOI Listing

Publication Analysis

Top Keywords

beam x-rays
20
μm values
20
attenuation coefficient
12
effective energies
12
values
9
μm
9
computed tomography-based
8
tomography-based attenuation
8
attenuation correction
8
bilinear scaling
8

Similar Publications

Convergent-beam attosecond x-ray crystallography.

Struct Dyn

January 2025

Center for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22607 Hamburg, Germany.

Sub-ångström spatial resolution of electron density coupled with sub-femtosecond to few-femtosecond temporal resolution is required to directly observe the dynamics of the electronic structure of a molecule after photoinitiation or some other ultrafast perturbation, such as by soft X-rays. Meeting this challenge, pushing the field of quantum crystallography to attosecond timescales, would bring insights into how the electronic and nuclear degrees of freedom couple, enable the study of quantum coherences involved in molecular dynamics, and ultimately enable these dynamics to be controlled. Here, we propose to reach this realm by employing convergent-beam x-ray crystallography with high-power attosecond pulses from a hard-x-ray free-electron laser.

View Article and Find Full Text PDF

Background The thyroid gland is the most susceptible organ to radiation during the exposure of teeth because the thyroid area appears to be within the primary beam, and the dose levels are relatively high even after using collimation. This study aims to develop an eco-friendly thyroid shield by reusing lead foils from intra-oral periapical radiographic films and evaluate its effectiveness in intraoral radiography. Methods A total of 16 patients undergoing endodontic procedures who gave written consent to participate in the study were included and divided into four categories: anterior, canine, premolar, and molar.

View Article and Find Full Text PDF

Objectives: This preclinical ex vivo porcine study aimed to evaluate the effects of two flap advancement techniques and periosteal suturing (PS) on graft material displacement during primary wound closure in guided bone regeneration (GBR). Secondary objectives included assessing flap advancement and the impact of soft tissue characteristics on graft displacement.

Materials And Methods: Standardized two-walled horizontal bone defects were created in second premolar sites of pig hemimandibles.

View Article and Find Full Text PDF

Evaluation of maxillary sinus pathologies and the posterior superior alveolar artery canal using cone-beam computed tomography.

BMC Oral Health

January 2025

Department of Oral and Maxillofacial Surgery, Ahmet Kelesoglu Faculty of Dentistry, Karaman, 70200, Türkiye.

Objective: This study aims to determine the anatomical relationship between the posterior superior alveolar artery (PSAA) and the lateral wall of the maxillary sinus during preoperative radiological evaluations in the posterior maxillary dental region, as well as to evaluate the prevalence of PSAA and its potential associations with sinus pathologies.

Materials And Methods: This retrospective study is based on the analysis of Cone-Beam Computed Tomography (CBCT) data from 510 sinuses of 255 patients. The visibility of the PSAA vascular canal, artery diameters, vertical distance between the alveolar crest and the artery, and the distance to the sinus floor were measured in coronal sections.

View Article and Find Full Text PDF

Introduction: SRS for the treatment of limited brain metastases (BM) is widely accepted, but there are still limitations in the management of numerous BM. Frameless single-isocenter multitarget SRS is a novel technique that allows for rapid treatment delivery to multiple BM. We report our preliminary clinical, dosimetric, and patient´s shifts outcomes with this technique.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!