Perioperative Predictors of Extubation Failure and the Effect on Clinical Outcome After Infratentorial Craniotomy.

Med Sci Monit

Department of Critical Care Medicine, Beijing Tiantan Hospital, Capital Medical University, Beijing, China (mainland).

Published: July 2016

BACKGROUND The purpose of the study was to analyze the risk factors for failed extubation in subjects submitted to infratentorial craniotomy. MATERIAL AND METHODS Patients aged over 18 years who received infratentorial craniotomy for brain tumor resection were consecutively included in this study. Perioperative variables were collected and analyzed. Univariate analyses and multiple logistic regression were used to derive factors related to failed extubation. Patients had follow-up care until either out of hospital or death. RESULTS Throughout the course of the study, 2118 patients were eligible and 94 (4.4%) suffered from extubation failure at some point during their hospital stay. Five factors were recognized as independent risk factors for postoperative failed extubation: craniotomy history, preoperative lower cranial nerve dysfunction, tumor size, tumor position, and maximum change in blood pressure (BP) during the operation. Failed extubation was related to a higher incidence rate of pneumonia, mortality, unfavorable Glasgow Outcome Scale score, longer stay in the neuro-intensive care unit (ICU) and hospitalization, and higher hospitalization costs compared with successful extubation. CONCLUSIONS History of craniotomy, preoperative lower cranial nerve dysfunction, tumor size, tumor position, and maximum change in BP during the operation were independent risk factors related to postoperative failed extubation in patients submitted to infratentorial craniotomy. Extubation failure raises the incidences of postoperative pneumonia, mortality, and higher hospitalization costs, and prolongs neuro-ICU and postoperative length of stay.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4944551PMC
http://dx.doi.org/10.12659/msm.899780DOI Listing

Publication Analysis

Top Keywords

failed extubation
20
infratentorial craniotomy
16
extubation failure
12
risk factors
12
extubation
9
factors failed
8
submitted infratentorial
8
extubation patients
8
independent risk
8
factors postoperative
8

Similar Publications

Complex biological systems undergo sudden transitions in their state, which are often preceded by a critical slowing down of dynamics. This results in longer recovery times as systems approach transitions, quantified as an increase in measures such as the autocorrelation and variance. In this study, we analysed paediatric patients in intensive care for whom mechanical ventilation was discontinued through removal of the endotracheal tube (extubation).

View Article and Find Full Text PDF

Objective: The Sedation and Weaning in Children (SANDWICH) trial of a sedation weaning and ventilator liberation bundle had a primary outcome of time to successful extubation, and showed significant but small difference. We explored the impact of the intervention on infants with bronchiolitis.

Design: Post hoc subgroup analysis of a cluster-randomized trial, 2018 to 2019 (ISRCTN16998143).

View Article and Find Full Text PDF

An 8-week-old, 3.4-kg infant, who was diagnosed prenatally with tetralogy of Fallot and absent pulmonary valve syndrome, was intubated after birth and failed extubation due to severe tracheobronchomalacia. He was deemed inoperable prior to being transferred to our institution.

View Article and Find Full Text PDF

Unlabelled: To evaluate the accuracy of the lung ultrasound score (LUS) in predicting ventilatory weaning failure during neonatal hospitalization in the NICU and to identify factors associated with weaning failure, including corrected gestational age (CGA). This prospective, longitudinal, pragmatic and observational cohort study included neonates on mechanical ventilation for at least 48 h. The primary outcome was the accuracy of lung ultrasound in predicting 3-day weaning failure, with the ROC curve used to determine the best LUS cutoff (sensitivity and specificity).

View Article and Find Full Text PDF

Accuracy of lung ultrasound in predicting successful extubation in preterm infants born ≤ 25 weeks.

J Perinatol

January 2025

Neonatal Intensive Care Unit, Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, 518028, Guangdong Province, China.

Objective: The aim of this study was to examine the predictive value of the lung ultrasound score (LUS) for successful extubation in preterm infants born at ≤25 weeks.

Methods: This was a single-center, prospective cohort study. Preterm infants with gestational age (GA) ≤ 25 weeks who received invasive mechanical ventilation (IMV) for ≥72 h were included.

View Article and Find Full Text PDF