Objective: In recent years laser interstitial thermal therapy (LITT) has become the ablative neurosurgical procedure of choice. Multiple methods for registration and laser fiber verification have been described, with each method requiring multiple steps and significant time expenditure. We evaluated the use of a commercially available mobile computed tomography (CT) scanner for stereotactic registration during LITT for brain tumors in an attempt to simplify the procedure and improve intraoperative awareness of laser position.
Methods: This is a retrospective chart review comparing LITT of brain tumors in 23 patients undergoing a standard protocol requiring skull pins and transport of the patient to a CT suite to obtain a reference scan compared with 14 patients in whom the Medtronic O-arm was used intraoperatively for navigation registration and confirmation of laser position.
Results: Total ablation of the target was achieved in all patients with no surgical complications. Total surgery time was shorter for the O-arm group than for the standard protocol group, once experience was gained with bringing the O-arm in and out of the surgical field. Return from the magnetic resonance imaging suite to the operating room for repositioning of the laser was required for 1 patient in the standard protocol group, but for no patients in the O-arm group. Once experience was gained with using the O-arm, estimated surgical costs were lower for this group.
Conclusions: Use of a mobile intraoperative CT scanner for navigation registration and confirmation of laser position during LITT may play a role in streamlining the procedure and improving patient safety and comfort.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.wneu.2016.06.126 | DOI Listing |
Trials
December 2024
Liver Transplantation Center, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University and Collaborative Innovation Center of Biotherapy, Chengdu, 610041, China.
Background: Indocyanine green (ICG) is a near-infrared fluorescent dye widely used for intraoperative navigation during liver surgeries because of its non-radioactive nature, high safety, and minimal impact on liver function. However, variability in its dosage and concentration and its low imaging success rates have limited its widespread application. To address these issues, we developed a novel ICG-human serum albumin (ICG-HSA) complex to enhance fluorescence visualization during laparoscopic anatomical liver resection.
View Article and Find Full Text PDFJ Endod
December 2024
Division of Conservative Dentistry and Endodontics, Centre for Dental Education and Research, All India Institute of Medical Sciences, New Delhi-110029, India.
Introduction: The dynamic navigation system (DNS) in endodontics presents a significant learning curve. This cross-sectional study aimed to assess the number of cases required to achieve consistent performance in DNS-assisted treatment of maxillary anterior teeth with pulp canal calcification.
Methods: A series of DNS procedures were performed on 45 calcified maxillary anterior teeth with pulp necrosis by a single endodontist who had no prior clinical DNS experience.
Int J Comput Assist Radiol Surg
December 2024
Department of Cardiothoracic Surgery, Erasmus University Medical Center, Rotterdam, The Netherlands.
Purpose: In this feasibility study, we aimed to create a dedicated pulmonary augmented reality (AR) workflow to enable a semi-automated intraoperative overlay of the pulmonary anatomy during video-assisted thoracoscopic surgery (VATS) or robot-assisted thoracoscopic surgery (RATS).
Methods: Initially, the stereoscopic cameras were calibrated to obtain the intrinsic camera parameters. Intraoperatively, stereoscopic images were recorded and a 3D point cloud was generated from these images.
J Med Internet Res
December 2024
Hansung University, Seoul, Republic of Korea.
Background: As health care continues to evolve with technological advancements, the integration of artificial intelligence into clinical practices has shown promising potential to enhance patient care and operational efficiency. Among the forefront of these innovations are large language models (LLMs), a subset of artificial intelligence designed to understand, generate, and interact with human language at an unprecedented scale.
Objective: This systematic review describes the role of LLMs in improving diagnostic accuracy, automating documentation, and advancing specialist education and patient engagement within the field of gastroenterology and gastrointestinal endoscopy.
CNS Neurosci Ther
December 2024
Department of Psychiatry, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
Background: Non-invasive brain stimulation (NIBS), such as transcranial direct current stimulation (tDCS) and repetitive transcranial magnetic stimulation (rTMS), has emerged as a promising alternative in the precise treatment of clinical symptoms, such as the cognitive impairment of bipolar disorder (BD). Optimizing the neurocognitive effects by combining tDCS and rTMS to strengthen the clinical outcome is a challenging research issue.
Objective: In this randomized, controlled trial, we first combined tDCS and neuronavigated rTMS targeting the V1 region to explore the efficacy on neurocognitive function in BD patients with depressive episodes.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!