A cadaveric mechanical study of forearm stability after a new stabilizing procedure.

J Hand Surg Eur Vol

1 Department of Orthopaedic Surgery and Traumatology, University Hospital of Bicêtre, Le Kremlin-Bicêtre, France.

Published: May 2017

Download full-text PDF

Source
http://dx.doi.org/10.1177/1753193416656772DOI Listing

Publication Analysis

Top Keywords

cadaveric mechanical
4
mechanical study
4
study forearm
4
forearm stability
4
stability stabilizing
4
stabilizing procedure
4
cadaveric
1
study
1
forearm
1
stability
1

Similar Publications

In recent years, robotic assistance has become increasingly used and applied in minimally invasive surgeries. A new cooperative surgical robot system that includes a joystick-guided robotic scope holder was developed in this study, and its feasibility for use in minimally invasive abdominal surgery was evaluated in a preclinical setting. The cooperative surgical robot consists of a six-degree-of-freedom collaborative robot arm and a one-degree-of-freedom bidirectional telescopic end-effector specializing in surgical assistance.

View Article and Find Full Text PDF

Purpose: To evaluate the maximal load to failure, cyclic displacement, stiffness, and modes of failure of onlay subpectoral biceps tenodesis with an intramedullary unicortical metal button (MB) versus an inlay, all-suture Caspari-Weber (CW) technique.

Methods: Sixteen matched paired human cadaveric proximal humeri were randomly allocated for subpectoral BT with either CW or MB using a high-strength suture (N = 16; 8 male, 8 female, mean age = 82.5 years, range 62-99 years).

View Article and Find Full Text PDF

A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus.

Sci Rep

January 2025

Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.

In cases of large mandibular continuity defects resulting from malignancy resection, the current standard of care involves using patient-specific/custom titanium reconstruction plates along with autogenous grafts (fibula, scapula, or iliac crest segments). However, when grafts are not feasible or desired, only the reconstruction plate is used to bridge the gap. Unfortunately, metal osteosynthesis and reconstruction plates, including titanium, exhibit adverse effects such as stress-shielding and limitations in accurate postoperative irradiation (especially with proton-beam therapy).

View Article and Find Full Text PDF

Does Improved Resection Plane Coverage During Shoulder Arthroplasty Influence Proximal Humeral Bone Stress? A Comparison of Circular vs. Elliptical Humeral Heads.

J Shoulder Elbow Surg

December 2024

Department of Mechanical Engineering, Western University, London, ON, Canada; The Roth|McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada; Department of Surgery, Western University, London, ON, Canada. Electronic address:

Introduction: Stress shielding remains a concern following total shoulder arthroplasty using press-fit short humeral stems. While the effect of alterations in implant geometry, positioning, and sizing on stress shielding have been investigated, the effects of coverage of the cortical boundary of the resection plane have not yet been fully explored. The purpose of this study was to quantify the effect of improved cortical coverage using elliptical vs.

View Article and Find Full Text PDF
Article Synopsis
  • Up to 20% of people may experience osteoporotic vertebral fractures, and current bone mineral density (BMD) measurements present challenges in predicting these fractures.
  • The study examined how intervertebral disc (IVD) degeneration affects stress and strain distribution in adjacent vertebrae by using human cadaveric lumbar specimens and advanced imaging techniques.
  • Results indicated that trabecular bone near degenerated IVDs experienced significantly higher strains and altered stress distributions compared to non-degenerated IVDs, suggesting that incorporating IVD metrics could enhance fracture risk assessments.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!