A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of Diffusion Metrics Obtained at 1.5T and 3T in Human Brain With Diffusional Kurtosis Imaging. | LitMetric

Purpose: To quantitatively compare diffusion metrics for human brain estimated with diffusional kurtosis imaging (DKI) at applied field strengths of 1.5 and 3T.

Materials And Methods: DKI data for brain were acquired at both 1.5 and 3T from each of six healthy volunteers using a twice-refocused diffusion-weighted imaging sequence. From these data, parametric maps of mean diffusivity (MD), axial diffusivity (D ), radial diffusivity (D ), fractional anisotropy (FA), mean diffusional kurtosis (MK), axial kurtosis (K ), radial kurtosis (K ), and kurtosis fractional anisotropy (KFA) were estimated. Comparisons of the results from the two field strengths were made for each metric using both Bland-Altman plots and linear regression to calculate coefficients of determination (R ) and best fit lines.

Results: Diffusion metrics measured at 1.5 and 3T were observed to be similar. Linear regression of the full datasets had coefficients of determination varying from a low of R = 0.86 for KFA to a high of R = 0.97 for FA. The slopes of the 3T vs. 1.5T best linear fits varied from 0.881 ± 0.009 for KFA to 1.038 ± 0.010 for D . From a Bland-Altman analysis of selected regions of interest, the mean differences of the metrics for the two field strengths were all found to be less than 6%, except for KFA, which showed the largest relative discrepancy of 10%.

Conclusion: Diffusion metrics measured with DKI at 1.5 and 3T are strongly correlated and typically differ by only a few percent. The somewhat higher discrepancy for the KFA is argued to mainly reflect the effects of signal noise. This supports the robustness DKI results with respect to field strength.

Level Of Evidence: 3 J. Magn. Reson. Imaging 2017;45:673-680.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.25380DOI Listing

Publication Analysis

Top Keywords

diffusion metrics
16
diffusional kurtosis
12
field strengths
12
human brain
8
kurtosis imaging
8
fractional anisotropy
8
linear regression
8
coefficients determination
8
metrics measured
8
kurtosis
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!