AI Article Synopsis

  • - The study aimed to assess how different depths of dental implant penetration into the maxillary sinus cavity affect implant and sinus health in dogs, using a sample of four female dogs with eight titanium implants.
  • - After five months, all groups showed no inflammation, with the 1 mm protrusion group having full bone coverage, the 2 mm group partially covered, and the 3 mm group showing no bone formation or communication with the sinus cavity.
  • - The conclusion suggests that even with varying depths of penetration into the sinus, the implants did not negatively impact sinus health or stability in the canine model.

Article Abstract

Objective: The purpose of this study was to investigate the effect of the dental implant penetration into the maxillary sinus cavity in different depths on implant and sinus health in a dog model.

Materials And Methods: The study sample included eight titanium dental implant placed in four female dogs immediately after extraction of the first maxillary molar in the palatal socket and assigned into four groups according to the protruding of implant tips (control group A = 0 mm, and study groups B, C, and D with protrusion of 1, 2, and 3 mm, respectively). The bone blocks of the implants were harvested 5 months postoperatively and evaluated by cone beam computed tomography (CBCT) and histological analysis.

Results: The whole groups showed no signs of inflammation during the 5-month period of the study. The tips of the implants in group B with penetrating depths of 1 mm were found to be fully covered with newly formed bone. The tips of the implants in group C with penetrating depths of 2 mm were exposed in the sinus cavity and showed partially new bone coverage, while depths of 3 mm in group D were found to have no bone formation and the dental implant fixture sites were communicated with the sinus cavity. No significant differences were found among the groups regarding implant stability.

Conclusion: Despite the protrusion extents, penetration of dental implant into the maxillary sinus with membrane perforation does not compromise the sinus health and the implant in canine.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10006-016-0568-zDOI Listing

Publication Analysis

Top Keywords

dental implant
16
maxillary sinus
12
sinus cavity
12
penetration dental
8
implant
8
sinus health
8
tips implants
8
implants group
8
group penetrating
8
penetrating depths
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!