Post mortem storage is a necessary process for removal of pin bones without destruction of fillets, thereby avoiding volume and economic loss. However, the enzymes involved in loosening pin bones during storage have not been studied to a great extent. In this study, the activities and localization of MMPs in the connective tissue (CT) of pin bones dissected from fillet of salmon and cod were investigated. Interestingly, the enzyme activity profile in these two species was different during post mortem storage of fish fillets. Adding MMP inhibitor (GM6001) and serine protease inhibitor (Pefabloc) revealed different effects in the two species, suggesting different regulations in salmon and cod. In situ zymography with the same inhibitors verified MMP and serine protease activity in CT close to pin bone at early post mortem (6 h) in salmon. However, MMP inhibition was not evident in cod in this area at that time point. Immunohistochemistry further revealed MMP9 and MMP13 were located more to the outer rim of CT, facing the pin bone and adipose tissue, while MMP7 was more randomly distributed within CT in salmon. In contrast, all these three MMPs were randomly distributed in CT in cod. In summary, our study reveals different MMP enzyme profiles in salmon and cod in the pin bone area, influenced by serine proteases, and suggests that MMPs and serine proteases must be taken in consideration when studying the conditions for early pin bone removal.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5306258 | PMC |
http://dx.doi.org/10.1007/s10695-016-0264-9 | DOI Listing |
BMC Musculoskelet Disord
December 2024
Department of Trauma and Microreconstructive Surgery, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, 830054, China.
Background: The purpose of this study was to report the clinical and psychological outcomes of using a locking compression plate (LCP) as a sequential external fixator following the distraction phase in the treatment of tibial bone defects caused by fracture-related infection (FRI).
Methods: We retrospectively analyzed the clinical records and consecutive X-ray images of patients with tibial bone defects who were treated with an LCP as a sequential external fixator following the distraction phase, between June 2017 and December 2022. The ASAMI criteria were applied to assess the bone and functional outcomes, and postoperative complications were evaluated by using the Paley classification.
J Surg Orthop Adv
December 2024
McLaren-Flint, Flint, Michigan; Kettering University, Flint, Michigan.
In cases of cervical facet dislocations, traction is typically delivered in the acute setting with tongs attached to the skull via two pins. Although the pins are recommended to be inserted symmetrically in a neutral loading position, erroneous asymmetric pin placement has been documented in case reports, but its biomechanical implications are unknown. The current study utilized a human surrogate to evaluate the influence of asymmetrically placed pins in the axial or frontal planes.
View Article and Find Full Text PDFBMC Vet Res
November 2024
AniCura Tierklinik Thun, Thun, Switzerland.
Background: Spinal stabilization in dogs is challenging, and improper implant placement can result in significant morbidity. Objectives were to evaluate reliability of a ball-tipped probe for detection of breached versus non-breached pedicle drill tracts in a canine large breed cadaveric model. CT scans obtained from T6 to sacrum.
View Article and Find Full Text PDFZhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
November 2024
Department of Orthopedic Ward 7, Hunan Provincial People's Hospital (First Affiliated Hospital of Hunan Normal University), Changsha Hunan, 410000, P. R. China.
Objective: To investigate the effectiveness of sacroiliac screw implantation assisted by three-dimensional (3D) printed faceted honeycomb guide plate in the treatment of posterior pelvic ring fracture.
Methods: The clinical data of 40 patients with posterior pelvic ring fractures treated with sacroiliac screw implantation between December 2019 and December 2022 were retrospectively analyzed. Among them, 18 cases were treated with sacroiliac screws fixation assisted by 3D printed faceted honeycomb guide plate (guide plate group), and 22 cases were treated with sacroiliac screws percutaneously fixation under fluoroscopy (conventional group).
Injury
September 2024
Department of Orthopaedic and Trauma surgery, S. Andrea Hospital, University of Rome La Sapienza, Italy.
Introduction: Internal fixation in not-comminuted oblique and transverse olecranon fractures is commonly performed with tension band wiring. However, despite its high healing rate, this technique is associated with a high rate of complications, often requiring the removal of fixation devices in up to 80 % of cases. The aim of our study was to describe a surgical technique using eyelet pins that maintains the effectiveness of the classic tension band wiring while reducing intolerance or displacement of the fixation devices.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!