The quadricuspid aortic valve is a very uncommon malformation associated with aortic insufficiency, aortic stenosis, endocarditis, and ascending aortic dilatation. We report four cases of this aortic valve malformation. One patient with severe aortic regurgitation and moderate aortic dilatation required aortic valve replacement. Three patients had mild or moderate aortic insufficiency combined with moderate ascending aortic dilatation. These patients were referred to follow-up. The presented cases demonstrate that this aortic valve malformation may not be as rare as it appears and that attention must be paid to any quadricuspid findings during computed tomographic angiography and echocardiography.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4930867PMC
http://dx.doi.org/10.12945/j.aorta.2015.15.004DOI Listing

Publication Analysis

Top Keywords

aortic valve
20
aortic dilatation
16
aortic
12
ascending aortic
12
quadricuspid aortic
8
combined moderate
8
moderate ascending
8
dilatation report
8
report cases
8
aortic insufficiency
8

Similar Publications

One-year hemodynamic and clinical outcomes in self-expanding valves: Comparison of ACURATE neo2 versus ACURATE neo.

Cardiovasc Revasc Med

December 2024

Department of Cardiology and Catheterization Laboratories, Shonan Kamakura General Hospital, Okamoto 1370-1, Kamakura City, Kanagawa 247-8533, Japan. Electronic address:

Background/purpose: Transcatheter aortic valve replacement (TAVR) with ACURATE neo2 showed better hemodynamic outcomes by mitigating paravalvular leakage (PVL) compared with ACURATE neo, and revealed promising one-year outcomes in single-arm studies. However, studies comparing the hemodynamic and clinical outcomes of the two valves are still scarce. Therefore, this study aimed to compare the one-year hemodynamic and clinical outcomes between the neo2 and neo.

View Article and Find Full Text PDF

Lower mini-sternotomy: an approach for treating all valvulopathies?

Ann Thorac Surg

December 2024

Sorbonne University, Department of Cardiovascular and Thoracic Surgery, Institute of Cardiology, Pitié-Salpêtrière Hospital, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France.

Background: Lower mini-sternotomy offers the advantage of providing excellent visualization of the 4 cardiac cavities, allowing surgical treatment of aortic, mitral and tricuspid valves as well as any intra-cavitary procedure. Technical issues, as well as safety and echocardiographic results of this approach, are lacking. The aim of this retrospective study was to describe outcomes of lower mini-sternotomy to treat valvulopathies and other intracardiac surgeries.

View Article and Find Full Text PDF

Is connective tissue disorder a risk factor for durability after valve-sparing root replacement?

Semin Thorac Cardiovasc Surg

December 2024

Aortic Center, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH. Electronic address:

View Article and Find Full Text PDF

Background: Interleaflet haemorrhage (IH) plays a well-recognized detrimental role in calcified aortic valve disease (CAVD). However, IH-induced fibro-osteogenic responses in valvular interstitial cells (VICs) appear to be triggered under specific pathological conditions. Iron deficiency (ID), a common co-morbidity in CAVD, may influence these responses.

View Article and Find Full Text PDF

Aortitis, defined as inflammation of the aorta, can lead to aneurysms and dissections. Intra-operative sampling is essential for diagnosis, with many cases presenting asymptomatically as clinically isolated aortitis. Previous studies investigating aortitis in major aortic surgery have been limited by low intra-operative sampling.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!