Ulnar Nerve Tendon Transfers for Pinch.

Hand Clin

The Hand and Upper Extremity Center of Georgia, PC, Northside/Alpharetta Medical Campus, Suite 350, 3400A Old Milton Parkway, Alpharetta, GA 30005, USA.

Published: August 2016

Power and tip pinch are an integral part of intrinsic hand function that can be significantly compromised with dysfunction of the ulnar nerve. Loss of power pinch is one component that can significantly affect an individual's ability to perform simple daily tasks. Tip pinch is less affected, as this task has significant contributions from the median nerve. To restore power pinch, the primary focus must be on restoring the action of the adductor pollicis primarily, and if indicated the first dorsal interosseous muscle and flexor pollicis brevis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hcl.2016.03.007DOI Listing

Publication Analysis

Top Keywords

power pinch
12
ulnar nerve
8
pinch
5
nerve tendon
4
tendon transfers
4
transfers pinch
4
pinch power
4
pinch integral
4
integral intrinsic
4
intrinsic hand
4

Similar Publications

This article introduces an innovative multipurpose system that integrates a solar power plant with a coastal wind farm to generate refrigeration for refinery processes and industrial air conditioning. The system comprises multiple wind turbines, solar power plants, the Kalina cycle to provide partial energy for the absorption refrigeration cycle used in industrial air conditioning, and a compression refrigeration cycle for propane gas liquefaction. An extensive energy and exergy analysis was conducted on the proposed system, considering various thermodynamic parameters such as the solar power plant's energy output, the absorption chiller's cooling load, the electricity generated by the turbines, the wind turbines' power output, and the energy efficiency and exergy of each cycle within the system.

View Article and Find Full Text PDF

A 21-year-old male laborer sustained bilateral degloving injury of the hands with multiple digital amputations and devascularized digits. After X-rays, preliminary debridement was done, when digital amputations were completed, including index ray amputation on both sides. The next day, two anterolateral thigh (ALT) flaps and one second toe transfer were done to restore coverage in the palm and the web and reconstruct the lost thumb.

View Article and Find Full Text PDF

Unraveling EEG correlates of unimanual finger movements: insights from non-repetitive flexion and extension tasks.

J Neuroeng Rehabil

December 2024

Laboratory for Neuro- & Psychophysiology, Department of Neurosciences, KU Leuven, Leuven, Belgium.

Background: The loss of finger control in individuals with neuromuscular disorders significantly impacts their quality of life. Electroencephalography (EEG)-based brain-computer interfaces that actuate neuroprostheses directly via decoded motor intentions can help restore lost finger mobility. However, the extent to which finger movements exhibit distinct and decodable EEG correlates remains unresolved.

View Article and Find Full Text PDF

Background: The use of prophylactic closed-incisional negative pressure wound therapy after colorectal procedures has been shown to reduce postoperative wound complications and surgical site infection. We present our experience with a novel, closed-incision, mechanically powered negative pressure (MP-NPD) dressing after colorectal procedures.

Methods: This was a prospective, single-center, single-arm observational study assessing patient reported and wound healing outcomes of colorectal surgical incisions dressed with a MP-NPD.

View Article and Find Full Text PDF

The progress of power systems and electronic devices promotes the development of lead-free dielectric energy-storage material. Particularly, NaBiTiO-based ferroelectric ceramics featuring large spontaneous polarization as well as wide dielectric adjustability and stability are highly recognized as promising candidates. However, their large remanent polarization () and low electric breakdown strength () result in unsatisfactory recoverable energy density () and/or energy conversion efficiency (η), severely restricting their energy-storage applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!