Background: Few studies have investigated the accuracy of the ActiGraph (AG) GTX3 accelerometer for assessing children's sitting and standing time. The activPAL (aP) has an inclinometer function that enables it to distinguish between sitting/lying and standing; however, its accuracy for assessing sitting and standing in older children is unknown. This study validated the accuracy of these devices for estimating sitting and standing time in a school classroom against a criterion measure of direct observation (DO).
Findings: Forty children in grades 5-7 wore both devices while being video recorded during two school lessons. AG and aP data were simultaneously collected in 15-s epochs. Individual participant DO and aP data were recorded as total time spent sitting/lying, standing and stepping. AG data were converted into time spent sitting and standing using previously established cut-points. Compared with DO, the aP underestimated sitting time (mean bias = -1.9 min, 95 % LoA = -8.9 to 5.2 min) and overestimated standing time (mean bias = 1.8 min, 95% LoA = -9.6 to 13.3 min). The best-performing AG cut-point across both sitting and standing (<75 counts/15 s) was more accurate than the aP, underestimating sitting time (mean bias = -0.8 min, 95 % LoA = -10.5 to 9.9 min) and standing time (mean bias = -0.4 min, 95% LoA = -9.8 to 9.1 min), but was less precise as evidenced by wider LoAs and poorer correlations with DO (sitting r = 0.86 aP vs 0.80 AG; standing r = 0.78 aP vs 0.60 AG).
Conclusions: The aP demonstrated good accuracy and precision for assessing free-living sitting and standing time in classroom settings. The AG was most accurate using a cut-point of < 75 counts/15 s. Further studies should validate the monitors in settings with greater inter- and intra-individual variation in movement patterns.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4936228 | PMC |
http://dx.doi.org/10.1186/s12966-016-0402-x | DOI Listing |
Hum Mov Sci
December 2024
Univ. Lille, CNRS, UMR 9193 - SCALab, Sciences Cognitives et Sciences Affectives, F-59000 Lille, France. Electronic address:
Background And Aim: Sit-stand desks allow individuals to work in either sitting or standing position. While previous studies have reported better performance on the attention network test (ANT) while standing compared to sitting, the relationship between body sway induced by these positions and ANT performance remains unclear. In this study, we aimed to test and expect benefits of body sway (in terms of magnitude and complexity) and improvements in ANT performance when standing (e.
View Article and Find Full Text PDFPlast Reconstr Surg Glob Open
December 2024
From the Department of Plastic Surgery, University of California Irvine Medical Center, Orange, CA.
Background: Successful nipple-areolar complex (NAC) reconstruction greatly influences patient outcomes for transgender patients undergoing chest masculinization. Despite the recent rise in case volume, little is known on designing the ideal NAC that maintains its aesthetics in dynamic settings. This study aimed to examine the characteristics of male NACs and their dimensional variability to help develop guidelines on designing the neo-NAC.
View Article and Find Full Text PDFChild Care Health Dev
January 2025
Faculty of Health, Institute for Physical Activity and Nutrition, Deakin University, Geelong, Victoria, Australia.
Background: The study examined the longitudinal associations of sleep time, restrained time, back time and tummy time with development in a sample of infants using compositional data analysis.
Methods: Participants were a subsample of 93 parent-infant dyads from the Early Movers project in Edmonton, Canada. Parents completed a 3-day time-use diary at 2, 4 and 6 months of age.
Ergonomics
December 2024
CIDEFES, Faculdade de Educação Física e Desporto, Universidade Lusófona, Lisboa, Portugal.
Sitting time (ST) in the occupational domain has been linked to reduced wellbeing and quality-of-life. However, studies investigating the impact of reducing ST in these outcomes are scarce. An ancillary analysis using data from a RCT containing a 6-month sit-stand desk-based intervention, evaluated workers' changes in ST (objectively measured), and subjective wellbeing and quality-of-life.
View Article and Find Full Text PDFJ Orthop Sci
December 2024
Department of Sports Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8553, Japan. Electronic address:
Background: The reproducibility of dynamic balance is an essential component of athletic performance and injury prevention, although it is affected by sex differences. This study aimed to confirm the reproducibility of repeated dynamic balance measurements and ultrasonography assessments of the anterior tibiofibular gap that may contribute to changes in dynamic balance for each sex.
Methods: This was a longitudinal study involving 48 feet, with 12 men and 12 women.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!