Introduction: Pedicle screw fixation allows purchase of all three spinal columns without encroaching into the spinal canal improving fracture fixation, as well as deformity correction. Fortunately, neurologic injury associated with pedicle screw malposition is rare.
Case Presentation: A 19-year-old boy was surgically treated for severe right thoracic scoliosis associated with a Chiari Type 1 malformation and a C6 to T7 syringomyelia. Six months after the initial surgery, the patient was referred to our institution after three weeks of gait disturbances and repeated falls. Imaging showed the gross misplacement of the left T5 pedicle screw, which crossed the center of the vertebral canal. The initial surgery used a freehand technique of pedicle screw insertion, with anteroposterior and lateral postoperative X-ray control. During the surgery, no SEP modifications were noted during pedicle screw placement. However, after insertion of the second rod and scoliosis correction by posterior translation technique, SEP responses decreased considerably. Revision surgery was performed to remove the misplaced screw. During the first three months after screw removal, repeated clinical examinations showed progressive recovery of the neurological deficits. Gait and bladder functions were normal six months after screw removal, and clinical signs of spasticity disappeared. SEP explorations performed at final follow-up showed similar responses to those performed before the initial surgery for scoliosis correction.
Discussion And Evaluation: Neurologic injury associated with pedicle screw malposition is rare. In early or delayed neurological status worsening, intraoperative or postoperative imaging must be done to detect pedicle screw misplacement. In the current case, thanks to cobalt-chromium and titanium use, MRI and CT scan allowed good visualization of the spinal canal and spinal cord. Experimental studies have shown that neurophysiological monitoring of the spinal cord does not detect moderate compression. In that way, neurophysiological monitoring is an all-or-nothing technique which can misdiagnose early stage of spinal cord injuries. Major penetration of the spinal canal by pedicle screw may conduct to hardware removal.
Conclusions: In early or delayed neurological status worsening, intraoperative or postoperative imaging must be done to detect pedicle screw misplacement. In the current case, thanks to cobalt-chromium and titanium use, MRI and CT scan allowed good visualization of the spinal canal and spinal cord. Major penetration of the spinal canal by pedicle screw may conduct to hardware removal.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4929096 | PMC |
http://dx.doi.org/10.1186/s40064-016-2334-y | DOI Listing |
Chin J Traumatol
December 2024
Department of Orthopaedics, Xinhua Hospital of Zhejiang Province, The Second Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, 310003, China.
Purpose: Bone cement-reinforced fenestrated pedicle screws (FPSs) have been widely used in the internal fixation and repair of the spine with osteoporosis in recent years and show significant improvement in fixation strength and stability. However, compared with conventional reinforcement methods, the advantages of bone cement-reinforced FPSs remain undetermined. This article compares the effects of fenestrated and conventional pedicle screws (CPSs) combined with bone cement in the treatment of osteoporosis.
View Article and Find Full Text PDFJ Neurosurg Spine
January 2025
1Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona; and.
Objective: Mixed-reality (MR) applications provide opportunities for technical rehearsal, education, and estimation of surgical performance without the risk of patient harm. In this study, the authors provide a structured literature review on the current state of MR applications and their effects on neurosurgery training. They also introduce an MR prototype for neurosurgical spine training.
View Article and Find Full Text PDFGlobal Spine J
January 2025
Department of orthopaedics, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Brain Spine
December 2024
Department of Neurosurgery, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
Front Bioeng Biotechnol
December 2024
Department of Orthopaedics, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, China.
Objective: In the current study, to demonstrate the advantages of oblique lateral interbody fusion (OLIF), we focused on the therapeutics for lumbar spinal tuberculosis with the comparison of three treatments, including anterior approach, posterior approach, and OLIF combined with posterior percutaneous pedicle screw fixation.
Methods: This study included patients with lumbar spinal tuberculosis from July 2015 to June 2018. We divided these patients into three groups: 35 patients underwent an anterior-only approach (Group A), 36 patients underwent a posterior-only approach (Group B), and 31 patients underwent OLIF combined with posterior percutaneous pedicle screw fixation (Group C).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!