We use a microfluidic flow-focusing device with integrated electrodes for controlling the production of water-in-oil drops. In a previous work, we reported that very long jets can be formed upon application of AC fields. We now study in detail the appearance of the long jets as a function of the electrical parameters, i.e., water conductivity, signal frequency, and voltage amplitude. For intermediate frequencies, we find a threshold voltage above which the jet length rapidly increases. Interestingly, this abrupt transition vanishes for high frequencies of the signal and the jet length grows smoothly with voltage. For frequencies below a threshold value, we previously reported a transition from a well-behaved uniform jet to highly unstable liquid structures in which axisymmetry is lost rather abruptly. These liquid filaments eventually break into droplets of different sizes. In this work, we characterize this transition with a diagram as a function of voltage and liquid conductivity. The electrical response of the long jets was studied via a distributed element circuit model. The model allows us to estimate the electric potential at the tip of the jet revealing that, for any combination of the electrical parameters, the breakup of the jet occurs at a critical value of this potential. We show that this voltage is around 550 V for our device geometry and choice of flow rates.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4912565 | PMC |
http://dx.doi.org/10.1063/1.4954194 | DOI Listing |
Acta Biomater
January 2025
Central laboratory of Liaocheng People's Hospital, Liaocheng, Shandong, 252000, China. Electronic address:
Peripheral nerve injury (PNI) as a common clinical issue that presents significant challenges for repair. Factors such as donor site morbidity from autologous transplantation, slow recovery of long-distance nerve damage, and deficiencies in local cytokines and extracellular matrix contribute to the complexity of effective PNI treatment. It is extremely urgent to develop functional nerve guidance conduits (NGCs) as substitutes for nerve autografts.
View Article and Find Full Text PDFJ Phys Chem A
January 2025
University of Göttingen, Institute for Physical Chemistry, Tammannstraße 6, 37077,Göttingen Germany.
Rotational spectroscopy is an excellent tool for structure determination, which can provide additional insights into local electronic structure by investigating the hyperfine pattern due to nuclear quadrupole coupling. Jet-cooled molecules are good experimental benchmark targets for electronic structure calculations, as they are free of environmental effects. We report the rotational spectra of 2-chlorobenzaldehyde, 3-chlorobenzaldehyde, and 4-chlorobenzaldehyde, including a complete experimental description of the nuclear quadrupole coupling constants, which were previously not experimentally determined.
View Article and Find Full Text PDFSurg Laparosc Endosc Percutan Tech
January 2025
Department of Surgery, Division of Gastrointestinal Surgery, University of South Florida Morsani College of Medicine, Tampa, FL.
Background: Peroral endoscopic myotomy (POEM) is a well-established endoscopic treatment for achalasia, utilizing an endoscopic knife for dissection. Recently, new knives with an integrated water-jet (WJ) function have been introduced. This study aims to compare the technical, perioperative, and late postoperative outcomes between WJ knives and conventional (C) knives, which lack the WJ function, through a pairwise meta-analysis of published comparative studies.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Joint Institute for High Temperatures, Russian Academy of Sciences, 125412 Moscow, Russia.
This paper presents the initial results of the synthesis of β-GaO luminescent ceramics via plasma gas-thermal spraying synthesis, where low-temperature plasma of an argon and nitrogen mixture was employed. A direct current electric arc generator of high-enthalpy plasma jet with a self-aligning arc length and an expanding channel of an output electrode served as a plasma source. The feedstock material consisted of a polydisperse powder of monocrystalline β-GaO with particle sizes ranging from 5 to 50 μm.
View Article and Find Full Text PDFJ Gastroenterol
December 2024
Department of Gastroenterological Endoscopy, Tokyo Medical University, Shinjuku-ku, Tokyo, Japan.
Background: Despite accumulating evidence and recommendations for management of colonic diverticular bleeding (CDB), the changes in its clinical management and outcomes remain unknown.
Methods: We performed a retrospective tendency analysis on a biennial basis, a propensity score-matched cohort study between the first and latter half groups, and mediation analyses to compare the diagnostic and treatment methods between January 2010 and December 2019 (CODE BLUE-J Study).
Results: A total of 6575 patients with CDB were included.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!