A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Using a double-channel gastroscope reduces procedural time in performing gastric endoscopic submucosal dissection. | LitMetric

Objective: Complications are important determining factors for safety of endoscopic submucosal dissection (ESD). ESD of large lesions is associated with increased procedural time. This study investigated whether double-channel gastroscope could be used to reduce procedural time in gastric antrum ESD.

Methods: A retrospective cohort study of 46 patients with one gastric antrum lesion resected by ESD was conducted between January 2013 and December 2015. The diameter of a lesion was from 2cm to 4cm in 46 patients. EUS before ESD was used to evaluate the submucosal vascular structure and the location of lesion in gastric wall. Forty six lesions had ESD with either the ordinary gastroscope (OS group) (n=24) or the double-channel gastroscope (DC group) (n=22).

Results: The mean procedural time was significantly lower in the DC group than in the OS group (49.1 minutes vs. 20.5 minutes, p=0.04). There were no significant differences in submucosal injection frequency, specimen size, en bloc resection rate and perforation rate between the two endoscopic groups. There was no recurrence in any case during the follow-up period.

Conclusions: Our data suggest that ESD utilizing double-channel gastroscope may provide a better platform for quicker ESD with equal safety.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4928410PMC
http://dx.doi.org/10.12669/pjms.323.9743DOI Listing

Publication Analysis

Top Keywords

double-channel gastroscope
16
procedural time
16
endoscopic submucosal
8
submucosal dissection
8
gastric antrum
8
gastroscope group
8
esd
7
double-channel
4
gastroscope reduces
4
procedural
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!