A disadvantage of spontaneous breathing through an endotracheal tube (ETT) and connector attached to a breathing circuit and/or ventilator (breathing device) is an increase in the work of breathing. The work of breathing associated with ETT of 6 to 9-mm diameter and eight breathing devices was determined, using a lung simulator to mimic spontaneous inspiration at flow rates of 20 to 100 L/min and a tidal volume of 500 ml, at both zero end-expiratory pressure (ZEEP) and 10 cm H2O continuous positive airway pressure (CPAP). Work associated with the breathing devices alone (WCIR) ranged from -0.002 kg.m/L (Servo 900-C ventilator, 7-mm ETT, 20 L/min, ZEEP) to 0.1 kg.m/L (continuous flow circuit, 7-mm ETT, 100 L/min, CPAP), the latter representing 196% of the work of normal breathing. When the devices were attached to ETT, total apparatus work (WAPP) ranged from 0.009 kg.m/L (Mapleson-D circuit, 9-mm ETT, 20 L/min, ZEEP) to 0.25 kg.m/L (Drager EV-A, 6-mm ETT, 100 L/min, ZEEP), the latter representing 490% of the work of normal breathing. This additional work imposed by the ETT varied considerably among devices. Spontaneous breathing through modern ventilators, circuits and ETT imposes a burden of increased work, most of which is associated with the presence of the ETT and connector. Whether this burden represents an impediment to the weaning patient, or has training value for the ultimate resumption of unassisted spontaneous ventilation, remains to be determined.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00003246-198907000-00015DOI Listing

Publication Analysis

Top Keywords

breathing
12
work breathing
12
breathing devices
12
100 l/min
12
l/min zeep
12
ett
10
additional work
8
spontaneous breathing
8
ett connector
8
work
8

Similar Publications

Mitochondrial electron transport chain (ETC) function modulates macrophage biology; however, mechanisms underlying mitochondria ETC control of macrophage immune responses are not fully understood. Here, we report that mutant mice with mitochondria ETC complex III (CIII)-deficient macrophages exhibit increased susceptibility to influenza A virus (IAV) and LPS-induced endotoxic shock. Cultured bone marrow-derived macrophages (BMDMs) isolated from these mitochondria CIII-deficient mice released less IL-10 than controls following TLR3 or TLR4 stimulation.

View Article and Find Full Text PDF

Effects of Variable Ventilation on Gas Exchange in an Experimental Model of Capnoperitoneum: A Randomized Crossover Study.

Anesth Analg

January 2025

From the Unit for Anaesthesiological Investigations, Department of Anaesthesiology, Pharmacology, Intensive Care and Emergency Medicine, University of Geneva, Geneva, Switzerland.

Background: The rapid advancement of minimally invasive surgical techniques has made laparoscopy a preferred alternative because it reduces postoperative complications. However, inflating the peritoneum with CO2 causes a cranial shift of the diaphragm decreasing lung volume and impairing gas exchange. Additionally, CO2 absorption increases blood CO2 levels, further complicating mechanical ventilation when the lung function is already compromised.

View Article and Find Full Text PDF

Clinical Evaluation of 3D Motion-Correction Via Scout Accelerated Motion Estimation and Reduction Framework Versus Conventional T1-Weighted MRI at 1.5 T in Brain Imaging.

Invest Radiol

January 2025

From the Department of Neuroradiology, University Medical Center Mainz, Johannes Gutenberg University, Mainz, Germany (L.S.L., K.H.H., A.K., M.A.B., S.A., A.E.O.); Institute of Medical Biostatistics, Epidemiology, and Informatics, University Medical Center Mainz, Johannes Gutenberg University, Mainz, Germany (R.H.P.); and Siemens Healthineers AG, Forchheim, Germany (D.P., D.N.S.).

Objectives: The aim of this study was to investigate the occurrence of motion artifacts and image quality of brain magnetic resonance imaging (MRI) T1-weighted imaging applying 3D motion correction via the Scout Accelerated Motion Estimation and Reduction (SAMER) framework compared with conventional T1-weighted imaging at 1.5 T.

Materials And Methods: A preliminary study involving 14 healthy volunteers assessed the impact of the SAMER framework on induced motion during 3 T MRI scans.

View Article and Find Full Text PDF

Background: This study aimed to investigate the association between Obstructive Sleep Apnea (OSA) and Tinnitus using NHANES data from 2005 to 2020.

Methods: This study analyzed data from NHANES (National Health and Nutrition Examination Surveys) conducted between 2005 and 2020, and included 4871 participants aged 16 or older. OSA was assessed using the Multivariate Apnea Prediction Index and the variables from the National Health and Nutrition Examination Survey.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!