Objectives: To determine perfusion computed tomography (P-CT) findings for distinction of arterial pseudolesions (APL) from hepatocellular carcinoma (HCC) in the cirrhotic liver.

Methods: 32 APL and 21 HCC in 20 cirrhotic patients (15 men; 65 ± 10 years), who underwent P-CT for evaluation of HCC pre- (N = 9) or post- (N = 11) transarterial chemoembolization, were retrospectively included using CT follow-up as the standard of reference. All 53 lesions were qualitatively (visual) and quantitatively (perfusion parameters) analysed according to their shape (wedge, irregular, nodular), location (not-/adjunct to a fistula), arterial liver perfusion (ALP), portal venous liver perfusion (PLP), hepatic perfusion index (HPI). Accuracy for diagnosis of HCC was determined using receiver operating characteristics.

Results: 18/32 (56 %) APL were wedge shaped, 10/32 (31 %) irregular and 4/32 (12 %) nodular, while 11/21 (52 %) HCC were nodular or 10/21 (48 %) irregular, but never wedge shaped. Significant difference between APL and HCC was seen for lesion shape in pretreated lesions (P < 0.001), and for PLP and HPI in both pre- and post-treated lesions (all, P < 0.001). Diagnostic accuracy for HCC was best for combined assessment of lesion configuration and PLP showing an area under the curve of 0.901.

Conclusion: Combined assessment of lesion configuration and portal venous perfusion derived from P-CT allows best to discriminate APL from HCC with high diagnostic accuracy.

Key Points: • Arterio-portal shunting is common in the cirrhotic liver, especially after local treatment. • Arterial pseudolesions (APL) due to shunting might mimic hepatocellular carcinoma (HCC). • Perfusion-CT allows for qualitative and quantitative assessment of liver lesions. • Lesion configuration fails to discriminate APL from HCC in locally treated patients. • Integration of quantitative perfusion analysis improves accuracy for diagnosis of HCC.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-016-4432-1DOI Listing

Publication Analysis

Top Keywords

liver perfusion
12
perfusion computed
8
computed tomography
8
hepatocellular carcinoma
8
hcc cirrhotic
8
apl hcc
8
wedge shaped
8
perfusion
6
hcc
6
arterio-portal shunts
4

Similar Publications

Unlabelled: Accurate estimation of the Lung Shunt Fraction (LSF) is a standard of care in yttrium-90 ( Y) radioembolization treatment planning to prevent excessive lung irradiation due to arterio-venous shunting in the liver. LSF is assessed using Tc macroaggregated albumin ( Tc-MAA) imaging, but this approach adds risk, complexity, and expense to the treatment planning. This study investigates the potential of Contrast-Enhanced Computed Tomography (CECT) as a non-invasive alternative for LSF estimation.

View Article and Find Full Text PDF

The American Transplant Congress (ATC) 2024, held in Philadelphia, serves as a vital platform for unveiling new research and clinical experience in organ machine perfusion-a key area in organ transplantation. This year's congress gathered 4652 participants from 49 countries, including top experts, to spotlight innovations in machine perfusion across various organ types, such as the liver, kidney, heart, and lung. A total of 87 abstracts on organ machine perfusion were presented.

View Article and Find Full Text PDF

Hepatic insulin clearance is essential for maintaining glucose homeostasis and is closely linked to metabolic disorders such as obesity, insulin resistance, and diabetes. Accurate measurement of insulin clearance is vital for understanding the underlying mechanisms of these conditions. This protocol presents a straightforward and user-friendly hepatic perfusion procedure in mice, specifically designed to directly evaluate the hepatic insulin clearance rate.

View Article and Find Full Text PDF

Danger Biomarkers in Perfusates From Fatty Liver Grafts Subjected to Cold Storage Preservation in Different Preservation Solutions.

Transplant Proc

January 2025

Experimental Pathology Department, Institut d'Investigacions Biomèdiques de Barcelona (IIBB)-CSIC, Barcelona, Spain; Steatohepatitis and Liver Transplant, Institut d'Investigacions Biomediques August Pi i Sunyer (IDIBAPS), CIBER ehd, Barcelona, Spain.

Static cold storage remains the traditional standard for liver graft preservation prior to transplantation in both clinical and experimental settings. The use of polyethylene glycol 35 solutions, such as Institut Georges Lopez-2 (IGL2) preservation solution, for protecting against mitochondrial damage during cold static preservation necessitates combination with hypothermic oxygenated perfusion to enhance liver graft performance. This study presents a preliminary comparative evaluation of "danger signals" indicating hepatocellular injury (transaminases, lactate content), mitochondrial damage (glutamate dehydrogenase release), and cytokine release in liver perfusates from suboptimal grafts (fatty livers) subjected to 24-hour cold storage.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!