Development of a Calibration Strip for Immunochromatographic Assay Detection Systems.

Sensors (Basel)

State Key Laboratory of Analog and Mixed Signal VLSI, University of Macau, Macau 999078, China.

Published: June 2016

With many benefits and applications, immunochromatographic (ICG) assay detection systems have been reported on a great deal. However, the existing research mainly focuses on increasing the dynamic detection range or application fields. Calibration of the detection system, which has a great influence on the detection accuracy, has not been addressed properly. In this context, this work develops a calibration strip for ICG assay photoelectric detection systems. An image of the test strip is captured by an image acquisition device, followed by performing a fuzzy c-means (FCM) clustering algorithm and maximin-distance algorithm for image segmentation. Additionally, experiments are conducted to find the best characteristic quantity. By analyzing the linear coefficient, an average value of hue (H) at 14 min is chosen as the characteristic quantity and the empirical formula between H and optical density (OD) value is established. Therefore, H, saturation (S), and value (V) are calculated by a number of selected OD values. Then, H, S, and V values are transferred to the RGB color space and a high-resolution printer is used to print the strip images on cellulose nitrate membranes. Finally, verification of the printed calibration strips is conducted by analyzing the linear correlation between OD and the spectral reflectance, which shows a good linear correlation (R² = 98.78%).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4970057PMC
http://dx.doi.org/10.3390/s16071007DOI Listing

Publication Analysis

Top Keywords

detection systems
12
calibration strip
8
assay detection
8
icg assay
8
characteristic quantity
8
analyzing linear
8
linear correlation
8
detection
6
development calibration
4
strip
4

Similar Publications

Synthetic Lipid Biology.

Chem Rev

January 2025

Weill Institute for Cell and Molecular Biology, Cornell University, Ithaca, New York 14853, United States.

Cells contain thousands of different lipids. Their rapid and redundant metabolism, dynamic movement, and many interactions with other biomolecules have justly earned lipids a reputation as a vexing class of molecules to understand. Further, as the cell's hydrophobic metabolites, lipids assemble into supramolecular structures─most commonly bilayers, or membranes─from which they carry out myriad biological functions.

View Article and Find Full Text PDF

Spatial occurrence of emerging contaminants in rivers and wastewater. Analysis of environmental and human risks.

Environ Toxicol Chem

January 2025

Laboratorio de Desarrollo Analítico y Quimiometría (LADAQ), Cátedra de Química Analítica I, Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral (UNL), Santa Fe, Argentina.

This study assesses the occurrence of emerging contaminants (ECs) from agricultural and livestock production activities along the Salado River (Santa Fe province, Argentina). Of the 23 ECs studied, 8 were detected and quantified in river and wastewater samples, including ciprofloxacin, enrofloxacin, chlorpyrifos-methyl, albendazole, fenbendazole, levamisole, diazepam, and thiamethoxam. In river samples, the highest concentrations corresponded to ciprofloxacin, chlorpyrifos-methyl, and enrofloxacin.

View Article and Find Full Text PDF

Rabies transmitted from vampires to cattle: An overview.

PLoS One

January 2025

Department of Fish and Wildlife Conservation, Virginia Tech, Blacksburg, VA, United States of America.

Rabies is a zoonotic infectious disease of global distribution that impacts human and animal health. In rural Latin America, rabies negatively impacts food security and the economy due to losses in livestock production. The common vampire bat, Desmodus rotundus, is the main reservoir and transmitter of rabies virus (RABV) to domestic animals in Latin America.

View Article and Find Full Text PDF

Annual surveys of refugees in Gambella, Ethiopia suggest that anemia is a persistent public health problem among non-pregnant women of reproductive age (NP-WRA, 15-49 years). Measurement of anemia in most refugee camp settings is conducted using an invasive HemoCue 301. We assessed the accuracy and precision of a non-invasive, pulse CO-oximeter in measuring anemia among NP-WRA in four Gambella refugee camps.

View Article and Find Full Text PDF

The explosion of Internet-of-Thing enables several interconnected devices but also gives rise chance for unauthorized parties to compromise sensitive information through wireless communication systems. Covert communication therefore has emerged as a potential candidate for ensuring data privacy in conjunction with physical layer transmission to render two lines of defense. In this paper, we aim to enhance the individual transmission of nearby users in non-orthogonal multiple access (NOMA) systems under scenarios of an eavesdropper who monitors covert transmission before decoding covert information.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!