Objectives: Peristaltic pumps are increasingly employed during fill & finish operations of a biopharmaceutical drug, due to sensitivity of many biological products to rotary piston pump-related stresses. Yet, possibly also unit operations using peristaltic pumps may shed particulates into the final product due to abrasion from the employed tubing. It was the aim of this study to elucidate the potential influence of particles shed from peristaltic pump tubing on the stability of a drug product.

Methods: Spiking solutions containing shed silicone particles were prepared via peristaltic pumping of placebo under recirculating conditions and subsequently characterized. Two formulated antibodies were spiked with two realistic, but worst-case levels of particles and a 6-month accelerated stability study with storage at 2-8, 25 and 40°C were conducted.

Key Findings: Regarding the formation of aggregates and fragments, both mAbs degraded at their typically expected rates and no additional impact of spiked particles was observed. No changes were discerned however in turbidity, subvisible and visible particle assessments. Flow imaging data for one of the mAb formulations with spiked particles suggested limited colloidal stability of shed particles as indicated by a similar increase in spiked placebo.

Conclusions: Shed silicone particles from peristaltic pump tubing are assumed to not impair drug product stability.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jphp.12603DOI Listing

Publication Analysis

Top Keywords

peristaltic pumps
8
particles peristaltic
8
peristaltic pump
8
pump tubing
8
silicone particles
8
spiked particles
8
particles
7
stability
5
peristaltic
5
influence particle
4

Similar Publications

Establishment of a Low-Cost and Efficient In Vitro Model for Cultivating Intestinal Microbiota.

J Agric Food Chem

January 2025

Dongguan Key Laboratory of Environmental Medicine, School of Public Health, Guangdong Medical University, Dongguan 523808, China.

The Simulator of Human Intestinal Microbial Ecosystem (SHIME) has hindered widespread adoption due to its high cost. This study founded biomimetic multilink fermentation equipment (BMLFE), priced at half or even lower than SHIME. It was improved based on multilink fermentation equipment (MLFE) by modifying materials, peristaltic pumps, fermentation time, and dietary habits while calculating transfer time and volumes and conducted anaerobic fermentation for 15 days followed by monitoring changes in intestinal microbial composition and short-chain fatty acids (SCFAs).

View Article and Find Full Text PDF

A digital-movie-based flow colorimetry for pH measurement using a universal indicator has been applied to the end point detection of acid-base titrations. A two-channel flow system of feedback-based flow ratiometry, primarily consisting of two peristaltic pumps, a digital microscope-based detector, and a laptop computer, was constructed; a Visual Basic.NET program written in-house was used for automating the analytical processes.

View Article and Find Full Text PDF

The development of stable and standardized in vitro cytotoxicity testing models is essential for drug discovery and personalized medicine. Microfluidic technologies, recognized for their small size, reduced reagent consumption, and control over experimental variables, have gained considerable attention. However, challenges associated with external pumps, particularly inconsistencies between individual pumping systems, have limited the real-world application of cancer-on-a-chip technology.

View Article and Find Full Text PDF

Pump is a vital component for expelling the perfusate in small animal isolated organ normothermic machine perfusion (NMP) systems whose flexible structure and rhythmic contraction play a crucial role in maintaining perfusion system homeostasis. However, the continuous extrusion forming with the rigid stationary shaft of the peristaltic pumps can damage cells, leading to metabolic disorders and eventual dysfunction of transplanted organs. Here, we developed a novel biomimetic blood-gas system (BBGs) for preventing cell damage.

View Article and Find Full Text PDF

Preliminary steps for fabrication of microfluidic systems for swine sperm sorting: Materials, perfusing systems and flow.

Res Vet Sci

February 2025

Tissue Microenvironment (TME) Lab, Aragón Institute of Engineering Research (I3A), University of Zaragoza, 50018 Zaragoza, Spain; Institute for Health Research Aragón (IIS Aragón), 50009 Zaragoza, Spain. Electronic address:

The success rate of assisted reproductive techniques in the livestock production can be optimized by improving the quality of the semen sample by selecting only the good quality sperm from the ejaculate. Microfluidic technology has been studied for sperm sorting mainly in human ejaculates but has not been studied for boar sperm. Spermatozoa have been proven to be highly sensitive to different microplastics, but the potential toxic effects of the materials used to set up microfluidic systems have not been studied.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!