Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience.

PeerJ

Research Service, Veterans Affairs Medical Center, Washington, D.C., United States; Departments of Medicine, Biochemistry & Molecular Medicine, School of Medicine and Health Sciences, George Washington University, Washington, D.C., United States; Departments of Medicine and Rehabilitation Medicine, School of Medicine, Georgetown University, Washington, D.C., United States.

Published: July 2016

Background. Quantitative ultrasound measures are influenced by multiple external factors including examiner scanning force. Force feedback may foster the acquisition of reliable morphometry measures under a variety of scanning conditions. The purpose of this study was to determine the reliability of force-feedback image acquisition and morphometry over a range of examiner-generated forces using a muscle tissue-mimicking ultrasound phantom. Methods. Sixty material thickness measures were acquired from a muscle tissue mimicking phantom using B-mode ultrasound scanning by six examiners with varied experience levels (i.e., experienced, intermediate, and novice). Estimates of interrater reliability and measurement error with force feedback scanning were determined for the examiners. In addition, criterion-based reliability was determined using material deformation values across a range of examiner scanning forces (1-10 Newtons) via automated and manually acquired image capture methods using force feedback. Results. All examiners demonstrated acceptable interrater reliability (intraclass correlation coefficient, ICC = .98, p < .001) for material thickness measures obtained using force feedback. Individual examiners exhibited acceptable reliability with the criterion-based reference measures (ICC > .90, p < .001), independent of their level of experience. The measurement error among all examiners was 1.5%-2.9% across all applied stress conditions. Conclusion. Manual image capture with force feedback may aid the reliability of morphometry measures across a range of examiner scanning forces, and allow for consistent performance among examiners with differing levels of experience.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4924341PMC
http://dx.doi.org/10.7717/peerj.2146DOI Listing

Publication Analysis

Top Keywords

force feedback
24
interrater reliability
12
examiner scanning
12
quantitative ultrasound
8
feedback examiners
8
examiners varied
8
levels experience
8
morphometry measures
8
material thickness
8
thickness measures
8

Similar Publications

System-level wearable electronics require to be flexible to ensure conformal contact with the skin, but they also need to integrate rigid and bulky functional components to achieve system-level functionality. As one of integration methods, folding integration offers simplified processing and enhanced functionality through rigid-soft region separation, but so far, it has mainly been applied to modality of electrical sensing and stimulation. This paper introduces a vialess heterogeneous skin patch with multi modalities that separates the soft region and strain-robust region through folded structure.

View Article and Find Full Text PDF

Changes in winter precipitation accompanying emerging climate trends lead to a major carbon-climate feedback from Arctic tundra. However, the mechanisms driving the direction, magnitude, and form (CO and CH) of C fluxes and derived climate forcing (i.e.

View Article and Find Full Text PDF

Over 50% of individuals with lower limb loss report a fear of falling and avoiding daily activities partly due to a lack of plantar sensation. Providing direct somatosensory feedback via neural stimulation holds promise for addressing this issue. In this study, three individuals with lower limb loss received a sensory neuroprosthesis (SNP) that provided plantar somatosensory feedback corresponding to prosthesis-floor interactions perceived as arising from the missing foot generated by electrically activating the peripheral nerves in the residuum.

View Article and Find Full Text PDF

In a complex dynamical system, noise, feedback, and external forces shape behavior that can range from regularity to high-dimensional chaos. Multiple feedback sources can significantly alter its dynamics, potentially even suppressing the system's output. This study investigates the impact of competing feedback sources on a stochastic complex dynamical system using a photonic neuron-a diode laser with external optical feedback.

View Article and Find Full Text PDF

To curb the obesity epidemic, it is imperative that we improve our understanding of the mechanisms controlling fat mass and body weight regulation. While great progress has been made in mapping the biological feedback forces opposing weight loss, the mechanisms countering weight gain remain less well defined. Here, we integrate a mouse model of intragastric overfeeding with a comprehensive evaluation of the regulatory aspects of energy balance, encompassing food intake, energy expenditure, and fecal energy excretion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!