Background: Accelerometer-based computer navigation has been shown to be highly accurate for performing distal femoral and proximal tibial component alignment in total knee arthroplasty (TKA), although the procedure for the femoral component is less accurate than for the tibial component.

Methods: First, 30 knees without hip osteoarthritis or proximal femoral surgeries were selected. Sequential hip adduction, abduction, and flexion were performed, and the femoral head was monitored fluoroscopically in the coronal plane before TKA. Significantly more movement was detected during hip adduction than during abduction and flexion. Then, postoperative femoral and tibial component alignment was retrospectively evaluated in 48 TKAs before fluoroscopic monitoring (early group) and in the next 61 TKAs with femoral registration using smaller adduction movements to avoid large femoral head movements (later group). Another 47 TKAs treated with the conventional intramedullary method for the distal femoral component and the extramedullary method for the proximal tibial component were also analyzed (IM and EM group) for historic control.

Results: Significantly large variances in the femoral component implantation of the early group were detected in both the coronal and sagittal planes. The sagittal femoral implantation angle of the early group (4.6 ± 3.0°) was significantly larger than that of the later group (3.2 ± 1.8°) when 3.5° was the target for both groups. No significant difference was detected in the variances of either the coronal or sagittal tibial component implantation, although the coronal tibial implantation angle was significantly smaller (-1.3 ± 1.3°valgus) in the early group than in the other groups.

Conclusion: Accelerometer-based navigation sometimes has technical issues during registration associated with hip adduction. We showed that femoral registration without large adduction movements will enable more accurate femoral implantation. Surgeons should also keep in mind that the coronal tibial component is likely to be in valgus alignment (about 1°) even if a neutral angle (0°) is selected with this particular device.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2016.05.067DOI Listing

Publication Analysis

Top Keywords

tibial component
20
early group
16
femoral
13
distal femoral
12
femoral component
12
hip adduction
12
computer navigation
8
performing distal
8
total knee
8
knee arthroplasty
8

Similar Publications

Background: Despite advancements in prosthetic designs and surgical techniques, patellar dislocation remains a rare but significant complication following total knee arthroplasty, with an incidence ranging between 0.15% and 0.5%.

View Article and Find Full Text PDF

Patellar instability following total knee arthroplasty (TKA) is a rare, yet serious complication, potentially requiring revision surgery or resulting in chronic dysfunction. When encountered, it is paramount to understand the etiologies, diagnostic approaches, treatment options, and outcomes of the selected treatment. The most common cause of patella instability is improper positioning of components, leading to lateral maltracking of the patella.

View Article and Find Full Text PDF

Aims: Tibial fixation in revision total knee arthroplasty (rTKA) can present surgical challenges. It has been suggested that appropriate fixation in at least two of the three anatomical zones (epiphysis, metaphysis, and diaphysis) is essential for implant survival. However, supporting clinical data are lacking.

View Article and Find Full Text PDF

Background: The optimal soft tissue release technique for severe varus total knee arthroplasty (TKA) remains controversial. The technique of tibial plateau reduction was suggested for severe varus deformity during TKA. The purpose of this study was to evaluate the clinical and radiological outcomes of the technique of tibial plateau reduction.

View Article and Find Full Text PDF

Background: Ultracongruent (UC) total knee replacement (TKR) designs, serving as alternatives to posterior stabilized (PS) and cruciate retaining (CR) designs, lack conclusive evidence regarding posterior femoral rollback. This study aimed to compare intraoperative posterior femoral rollback and maximal knee flexion between UC and PS inserts, addressing the paucity of literature on femoral rollback achieved with UC designs in total knee replacement.

Methods: A consecutive cohort of 20 patients undergoing robotic-assisted primary total knee replacement, posterior femoral rollback and maximal intraoperative knee flexion were assessed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!