Biomolecular detection systems based on microfluidics are often called lab-on-chip systems. To fully benefit from the miniaturization resulting from microfluidics, one aims to develop 'from sample-to-answer' analytical systems, in which the input is a raw or minimally processed biological, food/feed or environmental sample and the output is a quantitative or qualitative assessment of one or more analytes of interest. In general, such systems will require the integration of several steps or operations to perform their function. This review will discuss these stages of operation, including fluidic handling, which assures that the desired fluid arrives at a specific location at the right time and under the appropriate flow conditions; molecular recognition, which allows the capture of specific analytes at precise locations on the chip; transduction of the molecular recognition event into a measurable signal; sample preparation upstream from analyte capture; and signal amplification procedures to increase sensitivity. Seamless integration of the different stages is required to achieve a point-of-care/point-of-use lab-on-chip device that allows analyte detection at the relevant sensitivity ranges, with a competitive analysis time and cost.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4986467PMC
http://dx.doi.org/10.1042/EBC20150013DOI Listing

Publication Analysis

Top Keywords

lab-on-chip systems
8
molecular recognition
8
systems integrated
4
integrated bioanalyses
4
bioanalyses biomolecular
4
biomolecular detection
4
systems
4
detection systems
4
systems based
4
based microfluidics
4

Similar Publications

Proteomics-on-a-Chip - Microfluidics meets proteomics.

Biosens Bioelectron

January 2025

The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, PR China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, PR China; TFX Group-Xi'an Jiaotong University Institute of Life Health, Xi'an 710049, PR China. Electronic address:

Proteomics provides an understanding of biological systems by enabling the detailed study of protein expression profiles, which is crucial for early disease diagnosis. Microfluidic-based proteomics enhances this field by integrating complex proteome analysis into compact and efficient systems. This review focuses on developing microfluidic chip structures for proteomics, covering on-chip sample pretreatment, protein extraction, purification, and identification in recent years.

View Article and Find Full Text PDF

Microsensor systems for cell metabolism - from 2D culture to organ-on-chip (2019-2024).

Lab Chip

January 2025

Laboratory for Electrical Instrumentation and Embedded Systems, IMTEK - Department of Microsystems Engineering, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany.

Cell cultures, organs-on-chip and microphysiological systems become increasingly relevant as models, , in drug development, disease modelling, toxicology or cancer research. It has been underlined repeatedly that culture conditions and metabolic cues have a strong or even essential influence on the reproducibility and validity of such experiments but are often not appropriately measured or controlled. Here we review microsensor systems for cell metabolism for the continuous measurement of culture conditions in microfluidic and lab-on-chip platforms.

View Article and Find Full Text PDF

Actinic keratosis (AK) is a precursor to invasive squamous cell carcinoma, making early diagnosis and treatment essential to prevent progression. Among available therapeutic options, nicotinamide (NAM) has shown potential in reducing AK progression. NAM is a precursor of nicotinamide adenine dinucleotide (NAD), which activates sirtuin (SIRT)1, a protein with anti-cancer properties.

View Article and Find Full Text PDF

Background: Endophthalmitis is an ophthalmologic emergency requiring accurate and rapid diagnosis for treatment. Currently, the diagnosis commonly relies on culture and molecular biology, which falls short of clinical rapid diagnosis. The purpose of this study was to evaluate the feasibility of a self-build Microfluidic Real-time Polymerase Chain Reaction (RT-PCR) System for rapidly identifying potential pathogens of endophthalmitis.

View Article and Find Full Text PDF

The upcoming era of flexible and wearable electronics necessitates the development of low-cost, flexible, biocompatible substrates amenable to the fabrication of active devices such as electronic devices, sensors and transducers. While natural biopolymers such as Silk are robust and biocompatible, long-term flexibility is a concern due to the inherent brittle nature of soft Silk thin films. This work elucidates the preparation and characterization of Silk-polyurethane (Silk-PU) composite film that provides long-duration flexibility.

View Article and Find Full Text PDF