Are assessments of damping capacity and placement torque useful in estimating root proximity of orthodontic anchor screws?

Am J Orthod Dentofacial Orthop

Professor and chair, Department of Orthodontics, Division of Clinical Research, Dental Research Center, School of Dentistry, Nihon University, Tokyo, Japan.

Published: July 2016

Introduction: Placement torque and damping capacity may increase when the orthodontic anchor screws make contact with an adjacent root. If this is the case, root contact can be inferred from the placement torque and damping capacity. The purpose of this study was to verify the detectability of root proximity of the screws by placement torque and damping capacity. For this purpose, we investigated the relationship among placement torque, damping capacity, and screw-root proximity.

Methods: The placement torque, damping capacity, and root proximity of 202 screws (diameter, 1.6 mm; length, 8.0 mm) were evaluated in 110 patients (31 male, 79 female; mean age, 21.3 ± 6.9 years). Placement torque was measured using a digital torque tester, damping capacity was measured with a Periotest device (Medizintechnik Gulden, Modautal, Germany), and root contact was judged using cone-beam computed tomography images.

Results: The rate of root contact was 18.3%. Placement torque and damping capacity were 7.8 N·cm and 3.8, respectively. The placement torque of screws with root contact was greater than that of screws with no root contact (P <0.05; effect size, 0.44; power, <0.8). Damping capacity of screws with root contact was significantly greater than that of screws with no root contact (P <0.01; effect size, >0.5; power, >0.95).

Conclusions: It was suggested that the damping capacity is related to root contact.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajodo.2015.12.018DOI Listing

Publication Analysis

Top Keywords

placement torque
36
damping capacity
32
torque damping
24
root contact
20
root proximity
12
torque
10
placement
9
root
9
capacity
8
orthodontic anchor
8

Similar Publications

: This study aimed to evaluate the primary stability, according to the insertion torque value (ITV) and resonance frequency analysis (RFA), of dental implants placed in standardized blocks of bone quality equivalent to type II-A bone, using three surgical undersized protocols of 0.2 mm, 0.5 mm, and 0.

View Article and Find Full Text PDF

Balance recovery schemes following mediolateral gyroscopic moment perturbations during walking.

PLoS One

December 2024

Lauflabor Locomotion Laboratory, Institute of Sport Science, Centre for Cognitive Science, Technische Universität Darmstadt, Hessen, Germany.

Maintaining balance during human walking hinges on the exquisite orchestration of whole-body angular momentum (WBAM). This study delves into the regulation of WBAM during gait by examining balance strategies in response to upper-body moment perturbations in the frontal plane. A portable Angular Momentum Perturbator (AMP) was utilized in this work, capable of generating perturbation torques on the upper body while minimizing the impact on the center of mass (CoM) excursions.

View Article and Find Full Text PDF

Background: Lumbar degenerative diseases are an important factor in disability worldwide, and they are also common among the elderly population. Stand-Alone Oblique Lumbar Interbody Fusion (Stand-Alone OLIF) is a novel surgical approach for treating lumbar degenerative diseases. However, long-term follow-up after surgery has revealed the risk of endplate collapse associated with Stand-Alone OLIF procedures.

View Article and Find Full Text PDF

[Biomechanical study of screw implant angle in reconstruction of tibiofibular syndesmosis injury].

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi

December 2024

Department of Orthopedics, the Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou Sichuan, 646000, P. R. China.

Objective: To investigate ideal screw implant angle in reconstruction of tibiofibular syndesmosis injury by using a biomechanical test.

Methods: A total of 24 ankle specimens from adult cadavers were used as the tibiofibular syndesmosis injury model. According to the angle of screw placement, the tibiofibular syndesmosis injury models were randomly divided into groups A (0°), B (10°-15°), C (20°-25°), and D (30°-35°), and the screws were placed at a level 2 cm proximal to the ankle joint.

View Article and Find Full Text PDF

Ridge dimensional changes and implant stability utilizing the osseodensification protocol: A randomized clinical trial.

J Periodontol

December 2024

Department of Periodontics and Dental Hygiene, University of Texas Health Science Center at Houston, School of Dentistry, Houston, Texas, USA.

Background: There is limited evidence on the effect of osseodensification drilling (OD) on alveolar ridge dimension changes and implant stability compared to standard drilling (SD). The purpose of this study was to compare the effect of both drilling protocols on ridge dimensional changes and implant stability.

Methods: Fifteen patients were recruited for a total of 20 pairs of implants.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!