A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An adaptation for exhaled breath condensate collection in rabbits. | LitMetric

Aim: To set up and test the feasibility of a handmade apparatus adapted for exhaled breath condensate (EBC) collection in medium-sized animals.

Materials And Methods: The apparatus was produced using an 18-mm thick u-shaped borosilicate glass. The u-shaped tube body is 25 cm in diameter, and the horizontal portions are 12 cm in diameter. The base consists of a tube joint 14/20 or 14 mm thick by 20 cm in diameter, and has a length of 5 cm. This has a hole that is plugged for condensate flow to a 1.5 mL polypropylene microtube that stores the condensate during collection. Was placed inside a styrofoam box and immersed in crushed ice and salt to ensure cooling. The temperature was monitored and maintained throughout the collection at -10°C. One of the outputs of the u-shaped tube was connected to the expiratory limb of the ventilator.

Results: An experimental model of ALI, induced by oleic acid (OA) was adopted to determine the concentration of biomarkers of oxidative stress: malondialdehyde (MDA), glutathione (GSH), and nitrite/nitrate (NOx). The proposed model allows measurement of NOx, MDA, and GSH. However, the NOx and MDA levels in the EBC were not significant. It was only possible to observe an upward trend, which suggests a temporal evolution of the presence of these markers in the EBC.

Conclusion: The EBC collection method adapted is effective to generate sufficient content that allows to determine the levels of different biomarkers, such as NOx, MDA, and GSH, that are involved in oxidative and inflammatory stress processes during respiratory diseases.

Download full-text PDF

Source
http://dx.doi.org/10.1080/01902148.2016.1196268DOI Listing

Publication Analysis

Top Keywords

nox mda
12
exhaled breath
8
breath condensate
8
condensate collection
8
ebc collection
8
u-shaped tube
8
mda gsh
8
collection
5
adaptation exhaled
4
condensate
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!