Elevated Angiopoietin-2 Level in Patients With Continuous-Flow Left Ventricular Assist Devices Leads to Altered Angiogenesis and Is Associated With Higher Nonsurgical Bleeding.

Circulation

From the Department of Medicine, Section of Cardiology (C.E.T., P.C., G.H.K., G.S., M.J.C., N.U., J.K.L.) and Department of Surgery, Section of Cardiac and Thoracic Surgery (V.T.), University of Chicago, IL; and Section of Cardiology, Michael E. DeBakey Veterans Affairs Medical Center, Houston, TX (S.E.F.).

Published: July 2016

Background: Nonsurgical bleeding is the most common adverse event in patients with continuous-flow left ventricular assist devices (LVADs) and is caused by arteriovenous malformations. We hypothesized that deregulation of an angiogenic factor, angiopoietin-2 (Ang-2), in patients with LVADs leads to increased angiogenesis and higher nonsurgical bleeding.

Methods: Ang-2 and thrombin levels were measured by ELISA and Western blotting, respectively, in blood samples from 101 patients with heart failure, LVAD, or orthotopic heart transplantation. Ang-2 expression in endothelial biopsy was quantified by immunofluorescence. Angiogenesis was determined by in vitro tube formation from serum from each patient with or without Ang-2-blocking antibody. Ang-2 gene expression was measured by reverse transcription-polymerase chain reaction in endothelial cells incubated with plasma from each patient with or without the thrombin receptor blocker vorapaxar.

Results: Compared with patients with heart failure or those with orthotopic heart transplantation, serum levels and endothelial expression of Ang-2 were higher in LVAD patients (P=0.001 and P<0.001, respectively). This corresponded to an increased angiogenic potential of serum from patients with LVADs (P<0.001), which was normalized with Ang-2 blockade. Furthermore, plasma from LVAD patients contained higher amounts of thrombin (P=0.003), which was associated with activation of the contact coagulation system. Plasma from LVAD patients induced more Ang-2 gene expression in endothelial cells (P<0.001), which was reduced with thrombin receptor blockade (P=0.013). LVAD patients with Ang-2 levels above the mean (12.32 ng/mL) had more nonsurgical bleeding events compared with patients with Ang-2 levels below the mean (P=0.003).

Conclusions: Our findings indicate that thrombin-induced Ang-2 expression in LVAD patients leads to increased angiogenesis in vitro and may be associated with higher nonsurgical bleeding events. Ang-2 therefore may contribute to arteriovenous malformation formation and subsequent bleeding in LVAD patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4942355PMC
http://dx.doi.org/10.1161/CIRCULATIONAHA.115.019692DOI Listing

Publication Analysis

Top Keywords

patients continuous-flow
8
continuous-flow left
8
left ventricular
8
ventricular assist
8
assist devices
8
higher nonsurgical
8
nonsurgical bleeding
8
patients heart
8
heart failure
8
orthotopic heart
8

Similar Publications

Left ventricular assist devices (LVADs) have been used as a bridge to transplantation in patients with advanced heart failure. In this case, LVAD therapy was used as a destination therapy for 16 years, representing the longest documented and continuously ongoing support with the original implanted device.

View Article and Find Full Text PDF

Introduction: Donor human milk (DHM) is the first alternative if mother's own milk is unavailable or contraindicated. Much DHM research has focused on its nutritional, immunological and biochemical composition in response to various maternal variables, standard human milk banking procedures and storage protocols. The current systematic review protocol, however, aims to systematically gather and analyse existing data pertaining to the impact of these aforementioned factors on the clinical, health-related and developmental outcomes observed in infants fed with DHM.

View Article and Find Full Text PDF

Background: The study assesses the feasibility of the DuoCor BiVAS, a novel biventricular assist system integrating magnetic levitation technology.

Methods: In an acute large animal model involving five sheep, each received the DuoCor BiVAS without cardiopulmonary bypass. Hemodynamic and device parameters were monitored continuously for 1-h post-implantation.

View Article and Find Full Text PDF

Clinical outcomes of modified left ventricular assist device driveline management.

J Artif Organs

December 2024

Departments of Cardiovascular Surgery, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita Shi, Osaka, Osaka fu, 565-0871, Japan.

Left ventricular assist devices (LVADs) are implanted in patients with heart failure to support cardiac circulation. However, no standardized methods have been established for LVAD driveline exit site management for the prevention of infections. Therefore, this study evaluated the efficacy of modified driveline management compared with that of conventional driveline management.

View Article and Find Full Text PDF

Aim: To evaluate the predictive value of preoperative echocardiographic parameters for occurrence of VAs in patients with preexisting ICD undergoing LVAD implantation.

Methods And Results: All consecutive patients (n = 264) with previous ICD who underwent LVAD surgery between May 2011 and December 2019 at our institution were included. The patients were predominantly male (89%) with NICM (59%) and a mean age of 59 ± 10 years.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!