Central Corneal Thickness and its Relationship to Intra-Ocular and Epidmiological Determinants.

J Coll Physicians Surg Pak

Resident Medical Officer, Urgent Care Centre, Alexandra Hospital, Cheadle, UK.

Published: June 2016

Objective: To measure central corneal thickness in Pakistani population and determine its relationship to intra-ocular pressure, age, gender and ethnicity.

Study Design: Cross-sectional observation study.

Place And Duration Of Study: Pakistan Institute of Medical Sciences, Islamabad, Pakistan, between December 2013 and February 2015.

Methodology: The right eyes of 1000 cases (496 males and 504 females) were recruited for this study. Inclusion criteria were Pashtun or Punjabi ethnicity, intra-ocular pressure < 22 mmHg, gonioscopically open angles, cup-disk-ratio < 0.5, and age matched normal visual fields. Cases with prior ocular surgery, contact lens use, corneal pathologies, myopia or hypermetropia > ±3.0 diopters, astigmatism of > ±1.0 diopters were excluded. Central corneal thickness was measured using a TopCon non-contact specular microscope. Intra-ocular pressure was measured using Goldmann applanation tonometer. Frequency distribution, test of significance, and regression analysis was carried out using Statistical Package for Social Sciences version 20.0.

Results: Mean age was 47.31 ±11.78 years. Ethnic composition was 51.6% (n=516) Pashtun and 48.4% (n=484) Punjabi. The mean central corneal thickness was 503.96 (±12.47) µm, while the mean intra-ocular pressure was 15.61 (±2.68) mmHg. Regression analysis showed a significant association between central corneal thickness and intra-ocular pressure (p=0.00) and age (p=0.00). A±100 µchange in central corneal thickness was associated with change in IOPof ±3.30 mmHg, whereas central corneal thickness decreased by 0.12 µm per year. No significant association could be established between central corneal thickness and ethnicity (p=0.19).

Conclusion: Central corneal thickness of the studied races was comparable to non-Caucasians which affects intra-ocular pressure measurements, and decreases with increasing age. No relationship was observed between central corneal thickness and ethnicity or gender.

Download full-text PDF

Source

Publication Analysis

Top Keywords

central corneal
40
corneal thickness
40
intra-ocular pressure
24
central
10
thickness
10
corneal
10
relationship intra-ocular
8
regression analysis
8
thickness ethnicity
8
intra-ocular
7

Similar Publications

Background: Increased reactive oxygen species (ROS) are involved in the pathological process of dry eye disease. Our previous results suggested that norepinephrine (NE) has a protective effect on dry eye.

Purpose: This study explored the potential therapeutic role and underlying mechanisms of NE in benzalkonium chloride (BAC)-induced dry eye disease.

View Article and Find Full Text PDF

Expression of Yes-associated protein in endothelial cells of human corneas before and after storage in organ culture.

Sci Rep

December 2024

Laboratory of Biology, Engineering, and Imaging for Ophthalmology, BiiO, Faculty of Medicine, University of Jean Monnet, 10 rue de la Marandière, 42270, Saint-Priest en Jarez, France.

The cornea, the anterior meniscus-shaped transparent and refractive structure of the eyeball, is the first mechanical barrier of the eye. Its functionality heavily relies on the health of its endothelium, its most posterior layer. The treatment of corneal endothelial cells (CECs) deficiency is allogeneic corneal graft using stored donor corneas.

View Article and Find Full Text PDF

Purpose: Neuropathic corneal pain (NCP) has been recognized as a distinct disease, yet treatment options remain limited. The aim of this pilot study was to explore the effectiveness of extranasal neurostimulation (EXNS) as a potential pain relief strategy for individuals with the peripheral component of NCP.

Methods: A retrospective study was performed to identify patients who were diagnosed with refractory peripheral or mixed NCP and subsequently underwent a single session of EXNS.

View Article and Find Full Text PDF

The pupillary direct and consensual reflex is an important non-invasive quick assessment of the neurological state of the eye. Currently, there is no cheap and affordable recording tool for screening and documentation of a relative afferent pupillary defect. We describe how to construct a frugal, do-it-yourself handheld scotopic binocular pupillometer device called Pupilmate.

View Article and Find Full Text PDF

We have compared the biomechanical properties of human and porcine corneas using vibrational optical coherence tomography (VOCT). The elastic modulus of the cornea has been previously reported in the literature to vary from about several kPa to more than several GPa based on the results of different techniques. In addition, the formation of corneal cones near the central cornea in keratoconus has been observed in the clinic.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!