Aims: Information about medication safety in pregnancy is inadequate. We aimed to develop a signal detection methodology to routinely identify unusual associations between medications and congenital anomalies using data collected by 15 European congenital anomaly registries.

Methods: EUROmediCAT database data for 14 950 malformed foetuses/babies with first trimester medication exposures in 1995-2011 were analyzed. The odds of a specific medication exposure (coded according to chemical substance or subgroup) for a specific anomaly were compared with the odds of that exposure for all other anomalies for 40 385 medication anomaly combinations in the data. Simes multiple testing procedure with a 50% false discovery rate (FDR) identified associations least likely to be due to chance and those associations with more than two cases with the exposure and the anomaly were selected for further investigation. The methodology was evaluated by considering the detection of well-known teratogens.

Results: The most common exposures were genitourinary system medications and sex hormones (35.2%), nervous system medications (28.0%) and anti-infectives for systemic use (25.7%). Fifty-two specific medication anomaly associations were identified. After discarding 10 overlapping and three protective associations, 39 associations were selected for further investigation. These associations included 16 which concerned well established teratogens, valproic acid (2) and maternal diabetes represented by use of insulin (14).

Conclusions: Medication exposure data in the EUROmediCAT central database can be analyzed systematically to determine a manageable set of associations for validation and then testing in independent datasets. Detection of teratogens depends on frequency of exposure, level of risk and teratogenic specificity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5137836PMC
http://dx.doi.org/10.1111/bcp.13056DOI Listing

Publication Analysis

Top Keywords

signal detection
8
associations
8
specific medication
8
medication exposure
8
medication anomaly
8
selected investigation
8
system medications
8
medication
7
anomaly
5
exposure
5

Similar Publications

Monolithic Multiparameter Terahertz Nano/Microdetector Based on Plasmon Polariton Atomic Cavity.

Adv Mater

January 2025

State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou, 510275, China.

Terahertz (THz) signals are crucial for ultrawideband communication and high-resolution radar, demanding miniaturized detectors that can simultaneously measure multiple parameters such as intensity, frequency, polarization, and phase. Traditional detectors fail to meet these needs. To address this, we introduce a plasmon polariton atomic cavity (PPAC) detector based on monolayer graphene, offering a multifunctional, monolithic, and miniaturized solution.

View Article and Find Full Text PDF

It has long been debated whether latent memory signals determine recognition judgments directly or through a small number of discrete states. Often, signal detection theory (SDT) models instantiate the former perspective, whereas the two-high-threshold (2HT) model instantiates the latter. Kellen and Klauer (2014) conducted a critical test using a ranking paradigm that yielded results in line with common SDT models and incompatible with the 2HT model.

View Article and Find Full Text PDF

Nexus: A versatile console for advanced low-field MRI.

Magn Reson Med

January 2025

Department 8.1 - Biomedical Magnetic Resonance, Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany.

Purpose: To develop a low-cost, high-performance, versatile, open-source console for low-field MRI applications that can integrate a multitude of different auxiliary sensors.

Methods: A new MR console was realized with four transmission and eight reception channels. The interface cards for signal transmission and reception are installed in PCI Express slots, allowing console integration in a commercial PC rack.

View Article and Find Full Text PDF

Modernizing power systems into smart grids has introduced numerous benefits, including enhanced efficiency, reliability, and integration of renewable energy sources. However, this advancement has also increased vulnerability to cyber threats, particularly False Data Injection Attacks (FDIAs). Traditional Intrusion Detection Systems (IDS) often fall short in identifying sophisticated FDIAs due to their reliance on predefined rules and signatures.

View Article and Find Full Text PDF

Transient shear wave elastometry using a portable magnetic resonance sensor.

Magn Reson Med

January 2025

MRI Research Centre, Physics, University of New Brunswick, Fredericton, New Brunswick, Canada.

Purpose: Magnetic resonance elastography (MRE) provides detailed maps of tissue stiffness, helping to diagnose various health conditions, but requires the use of expensive clinical MRI scanners. Our approach utilizes compact, cost-effective portable MR sensors that offer bulk characterization of material properties in a region of interest close to the surface (within 1-2 cm). This accessible instrument could enable routine monitoring and prevention of diseases not readily evaluated with conventional tools.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!