Experience with computerized tomography, used for the diagnosis of aortic aneurysm, is summarized. This diagnostic method is shown, on the basis of 137 cases, to be highly valuable for this pathology. The results of computerized tomography were compared to postoperative data, which demonstrated high accuracy in the measurement of the size of aortic aneurysm. Being a noninvasive diagnostic method that yields an accurate assessment of the aneurysm size, computerized tomography has advantages over other investigation methods. It is concluded that, unless a combined lesion of other vessels is suspected, preoperative investigation may be limited to computerized tomography alone.
Download full-text PDF |
Source |
---|
Foot Ankle Spec
January 2025
Department of Orthopaedic Surgery and Rehabilitation, Loyola University Medical Center, Maywood, Illinois.
Background: Owing to the risk for septic arthritis, traumatic arthrotomies are an urgent surgical problem for the treating orthopaedic surgeon. Traditionally, diagnosis is with the saline load test (SLT), although in the awake patient is an invasive and potentially painful procedure. While computerized tomography (CT) has been shown to be a reliable diagnostic tool for traumatic arthrotomies of other joints, its role has only recently been investigated in the setting of ankle arthrotomy.
View Article and Find Full Text PDFSci Rep
January 2025
Shandong Provincial Public Health Clinical Center, Shandong University, Jinan, 250013, Shandong, China.
Medical image annotation is scarce and costly. Few-shot segmentation has been widely used in medical image from only a few annotated examples. However, its research on lesion segmentation for lung diseases is still limited, especially for pulmonary aspergillosis.
View Article and Find Full Text PDFZhonghua Yi Xue Za Zhi
January 2025
Department of Urology, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing100730, China.
To compare the diagnostic value of fluorine 18-labelled prostate-specific membrane antigen (PSMA) PET/CT PRIMARY score and PSMA expression score for clinically significant prostate cancer (csPCa). The data of 70 patients with prostate cancer who underwent radical prostatectomy at Beijing Hospital from February 1, 2019 to February 29, 2024 were retrospectively analyzed. All patients underwent whole body F-PSMA PET/CT examination before surgery and pathological large sections of prostate specimens were made after surgery.
View Article and Find Full Text PDFZhonghua Yi Xue Za Zhi
January 2025
Department of Nuclear Medicine, Beijing Hospital, National Center of Gerontology; Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing100730, China.
To establish and validate a nomogram based on clinical characteristics and metabolic parameters derived from F-fluorodeoxyglucose positron emission tomography and computed tomography (F-FDG PET/CT) for prediction of high-grade patterns (HGP) in invasive lung adenocarcinoma. The clinical and PET/CT image data of 311 patients who were confirmed invasive lung adenocarcinoma and underwent pre-treatment F-FDG PET/CT scan in Beijing Hospital between October 2017 and March 2022 were retrospectively collected. The enrolled patients were divided into HGP group (196 patients) and non-HGP group (115 patients) according to the presence and absence of HGP.
View Article and Find Full Text PDFJMIR Med Inform
January 2025
Department of Emergency Medicine, University of Michigan, Ann Arbor, MI, United States.
Background: Studies suggest that less than 4% of patients with pulmonary embolisms (PEs) are managed in the outpatient setting. Strong evidence and multiple guidelines support the use of the Pulmonary Embolism Severity Index (PESI) for the identification of acute PE patients appropriate for outpatient management. However, calculating the PESI score can be inconvenient in a busy emergency department (ED).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!