A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Stereoelectroencephalography by using O-Arm and Vertek passive articulated arm: Technical note and experience of an epilepsy referral centre]. | LitMetric

Objective: To report a novel, accurate, and safe technique for deep brain electrode implantation to register brain electrical activity or SEEG, using frameless stereotaxy, neuronavigation assisted, and intraoperative CT-guided O-Arm and the Vertek articulated passive arm.

Material And Methods: All patients implanted by this technique in Barcelona Hospital Clinic were included. A prospective evaluation was made of the accuracy of the technique, as well as complications, surgical time, length of stay, and short-term outcomes.

Results: The study included 10 patients that underwent this procedure. The mean age was 38 years, and 60% were women. A mean of 6.9 (3-10) electrodes/patient, with a total of 69 electrodes, were implanted. The mean time for implantation was 34.7minutes per electrode. The mean distance between the planned target and the final target was 1.39 millimetres (0.95-1.7). There were no surgically derived complications. The epileptogenic zone was determined in 6 cases (60%). Surgical resection was performed in 5 cases (50%), with thermocoagulation in 3 (30%) cases, and in 2 cases (20%) there was no treatment. At a six-month follow-up of the 8 treated cases, 37.5% were ELAI I, 12.5% ELAI III, 25% ELAI IV, and 25% ELAI V.

Conclusions: The implantation of deep brain electrodes for SEEG by using intraoperative CT O-Arm and the Vertek articulated passive arm is a safe and effective technique with adequate accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.neucir.2016.05.002DOI Listing

Publication Analysis

Top Keywords

o-arm vertek
12
deep brain
8
vertek articulated
8
articulated passive
8
25% elai
8
cases
5
[stereoelectroencephalography o-arm
4
vertek passive
4
passive articulated
4
articulated arm
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!