Recent research suggests that circulating β-hydroxybutyrate (BHB) levels may be a meaningful indicator of grain intake and rumen development in pre-ruminant calves. As such, BHB levels may be a surrogate measure of rumen function to contribute to minimal weaning stress during the transition from liquid to solid feed. The primary objective of this study was to determine the optimal cut-point of circulating BHB levels that would be predictive of sufficient grain intake and rumen development for a successful transition from liquid to solid feed at the time of weaning. An additional objective was to validate the Precision Xtra (Abbott Diabetes Care, Abingdon, UK) calf-side test for determination of BHB in whole blood in calves around weaning, as compared with the gold standard laboratory method. A total of 20 Holstein female calves were randomly assigned at birth to be weaned at 6 wk (n=10) or 8 wk (n=10) of age. Milk replacer (mixed at 150 g/L) was offered at 1.2kg/calf per d in 2 meals until a 1-wk step down, when milk meals were reduced by 50% 1 wk before weaning. Daily measurements included the intakes of starter grain, chopped straw, and water. Weekly measurements included body weight and blood BHB, until 70 d of life. To assess digestive tract development, rumen fluid samples were taken before and after weaning (d 35, 49, and 63) and analyzed for ruminal short-chain fatty acids. Whole blood was collected by jugular venipuncture, and BHB was determined by the Precision Xtra test at calf-side. In addition, serum was separated from a clotted sample, frozen, and stored until laboratory analysis was performed. Laboratory BHB results were correlated with both the Precision Xtra test (r=0.95) and starter intake over 1 d (r=0.89), a 3-d average (r=0.90), and a 7-d average (r=0.90). Additionally, laboratory BHB results were associated with total ruminal volatile fatty acids (r=0.82), ruminal butyrate (r=0.77), and body weight (r=0.69). A receiver operating characteristic curve was created to plot the true positive rate against the false positive rate at 10μmol/L BHB intervals to determine the optimal cut-point of circulating BHB that is predictive of an average starter intake of 1,000 g/d over a 3-d period. The optimal combination of sensitivity (95.7%) and specificity (96.1%) was at 100µmol of BHB/L of blood. A value of 0.2 mmol/L on the Precision Xtra test yielded a sensitivity and specificity of 84.0 and 97.2%, respectively, over the 3-d average period of starter intake. These results show considerable promise for use of the Precision Xtra whole blood BHB test in the decision-making process of determining sufficient starter grain intake and rumen development for a successful transition from liquid to solid feed, and indicate that this test conducted at calf-side is highly accurate.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3168/jds.2016-11097 | DOI Listing |
J Dent
September 2024
Department of Restorative Dentistry, State University of Ponta Grossa, Uvaranas, Ponta Grossa, Paraná, Brazil. Electronic address:
Objective: Evaluate the penetration of hydrogen peroxide (HP) into the pulp chamber, bleaching efficacy (BE) and amount of gel expended during in-office bleaching using an applicator brush tip and conventional tip from different commercial brands.
Materials And Methods: 104 human premolars were randomly distributed into thirteen groups (n = 8) according to the commercial brand: DSP White Clinic 35 % Calcium (DW), Nano White 35 % (NW), Total Blanc One-Step 35 % (TS), Whiteness HP Blue 35 % (WB), Potenza Bianco Pro SS 38 % (PB), Opalescence XTra Boost 40 % (OB), no bleaching (negative control), and application method: applicator brush tip and conventional tip for all groups. Initial HP concentration (%) was determined via titration and pH was measured with digital pH meter.
Conserv Physiol
January 2024
Institute of Northern Engineering, University of Alaska Fairbanks, 1764 Tanana Loop, Fairbanks, Alaska 99775, USA.
We evaluated the Precision Xtra™ ketometer as part of a larger study categorizing fasting status of free-ranging Steller sea lion (; SSL) pups which necessitated the identification of plasma β-hydroxybutyrate concentrations ([β-HBA]) around a threshold of <0.3 and ≥0.3 mmol/l.
View Article and Find Full Text PDFFront Vet Sci
December 2023
Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, NC, United States.
Point-of-care (POC) glucose and β-hydroxybutyrate (β-HB) meters can potentially provide rapid insight into an elasmobranch's metabolic state in clinical and field research settings. This study evaluated the diagnostic agreement of three commercial POC meters against reference laboratory methods for glucose and β-HB concentrations in stingrays. Blood was collected during anesthetized exams from 28 stingrays representing four species: cownose rays (), Atlantic stingrays (), southern stingrays (), and yellow stingrays ().
View Article and Find Full Text PDFJ Pharm Biomed Anal
January 2024
University of Parma, Department of Chemistry, Life Sciences and Environmental Sustainability, Parco Area delle Scienze, 17/A, 43124 Parma, Italy.
Being able to facilitate retinal reattachment by preventing water migration into the subretinal space, silicone oils are widely used as long-term intraocular tamponade to treat cases of retinal detachment. Various commercial tamponades constituted by linear polydimethylsiloxane polymers with different molecular weights and cyclic impurities are available. In this study, for the first time, an untargeted headspace-gas-chromatography-mass spectrometry (HS-GC-MS) method was developed to identify low-molecular weight contaminants in three different types of silicone oil tamponades, namely Siluron 2000, RS-OIL ECS5000 and Densiron Xtra.
View Article and Find Full Text PDFJ Dairy Sci
November 2022
Department of Population Health and Reproduction, University of California, Davis 95616. Electronic address:
The objective of this prospective cohort study was to characterize the metabolic profile, health, milk production, and reproductive outcomes of cows diagnosed with hyperketonemia (HK; β-hydroxybutyrate ≥1.2 mmol/L), hypoglycemia (HG; glucose ≤2.2 mmol/L), or concurrent HK and HG (HKHG).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!