Generation of synthetic influent data to perform (micro)pollutant wastewater treatment modelling studies.

Sci Total Environ

CAPEC-PROCESS Research Center, Department of Chemical and Biochemical Engineering, Technical University of Denmark, Building 229, DK-2800 Kgs. Lyngby, Denmark. Electronic address:

Published: November 2016

The use of process models to simulate the fate of micropollutants in wastewater treatment plants is constantly growing. However, due to the high workload and cost of measuring campaigns, many simulation studies lack sufficiently long time series representing realistic wastewater influent dynamics. In this paper, the feasibility of the Benchmark Simulation Model No. 2 (BSM2) influent generator is tested to create realistic dynamic influent (micro)pollutant disturbance scenarios. The presented set of models is adjusted to describe the occurrence of three pharmaceutical compounds and one of each of its metabolites with samples taken every 2-4h: the anti-inflammatory drug ibuprofen (IBU), the antibiotic sulfamethoxazole (SMX) and the psychoactive carbamazepine (CMZ). Information about type of excretion and total consumption rates forms the basis for creating the data-defined profiles used to generate the dynamic time series. In addition, the traditional influent characteristics such as flow rate, ammonium, particulate chemical oxygen demand and temperature are also modelled using the same framework with high frequency data. The calibration is performed semi-automatically with two different methods depending on data availability. The 'traditional' variables are calibrated with the Bootstrap method while the pharmaceutical loads are estimated with a least squares approach. The simulation results demonstrate that the BSM2 influent generator can describe the dynamics of both traditional variables and pharmaceuticals. Lastly, the study is complemented with: 1) the generation of longer time series for IBU following the same catchment principles; 2) the study of the impact of in-sewer SMX biotransformation when estimating the average daily load; and, 3) a critical discussion of the results, and the future opportunities of the presented approach balancing model structure/calibration procedure complexity versus predictive capabilities.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2016.05.012DOI Listing

Publication Analysis

Top Keywords

time series
12
wastewater treatment
8
bsm2 influent
8
influent generator
8
influent
6
generation synthetic
4
synthetic influent
4
influent data
4
data perform
4
perform micropollutant
4

Similar Publications

Newborn screening for common genetic variants associated with permanent hearing loss: Implementation in Ontario and a review of the first 3 years.

Genet Med

January 2025

Newborn Screening Ontario, Children's Hospital of Eastern Ontario, Ottawa, ON, Canada; Children's Hospital of Eastern Ontario Research Institute, University of Ottawa, Ottawa. Electronic address:

Purpose: Universal newborn hearing screening (UNHS) programs using audiometric techniques alone are limited in ability to detect non-congenital childhood permanent hearing loss (PHL). In 2019, Ontario launched universal newborn screening (NBS) for PHL risk factors: congenital cytomegalovirus (cCMV) and 22 common variants in GJB2 and SLC26A4. Here we describe our experience with genetic risk factor screening.

View Article and Find Full Text PDF

Characterization and Detection Strategy Exploration in Cryptogenic Hepatocellular Carcinoma: Insights From a Super-Aged Region in Japan.

Cancer Med

January 2025

Division of Gastroenterology and Nephrology, Department of Multidisciplinary Internal Medicine, Faculty of Medicine, Tottori University, Yonago, Japan.

Background And Aim: In recent years, there has been a rise in cryptogenic hepatocellular carcinoma (c-HCC) cases in Japan, posing a detection challenge due to an unknown etiology. This study aims to enhance diagnostic strategies for c-HCC by analyzing its characteristics and exploring current opportunities for detection.

Methods: A retrospective study was conducted from April 2012 to March 2022, enrolling 372 newly diagnosed hepatocellular carcinoma (HCC) patients.

View Article and Find Full Text PDF

Background: Established risk models may not be applicable to patients at higher cardiovascular risk with a measured Lp(a) (lipoprotein[a]) level, a causal risk factor for atherosclerotic cardiovascular disease.

Methods: This was a model development study. The data source was the Nashville Biosciences Lp(a) data set, which includes clinical data from the Vanderbilt University Health System.

View Article and Find Full Text PDF

With contemporary anesthetic drugs, the efficacy of general anesthesia is assured. Health-economic and clinical objectives are related to reductions in the variability in dosing, variability in recovery, etc. Consequently, meta-analyses for anesthesiology research would benefit from quantification of ratios of standard deviations of log-normally distributed variables (e.

View Article and Find Full Text PDF

Purpose: MR-based FID navigators (FIDnavs) do not require gradient pulses and are attractive for prospective motion correction (PMC) due to short acquisition times and high sampling rates. However, accuracy and precision are limited and depend on a separate calibration measurement. Besides FIDnavs, stationary NMR field probes are also capable of measuring local, motion-induced field changes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!