Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: To determine security and benefits of high pressure postdilatation (HPP) of bioresorbable vascular scaffolds (BVS) in percutaneous coronary intervention (PCI) of complex lesions whatever its indication is.
Background: Acute scaffold disruption has been proposed as the main limitation of BVS when they are overexpanded. However, clinical implications of this disarray are not yet clear and more evidence is needed.
Methods: A total of 25 BVS were deployed during PCI of 14 complex lesions after mandatory predilatation. In all cases HPP was performed with NC balloon in a 1:1 relation to the artery. After that, optical coherence tomography (OCT) analyses were performed.
Results: Mean and maximal postdilatation pressure were 17±3.80 and 20 atmospheres (atm) respectively. Postdilatation balloon/scaffold diameter ratio was 1.01. A total of 39,590 struts were analyzed. Mean, minimal and maximal scaffold diameter were respectively: 3.09±0.34mm, 2.88±0.31mm and 3.31±0.40mm. Mean eccentricity index was 0.13±0.05. ISA percentage was 1.42% with a total of 564 malapposed struts. 89 struts were identified as disrupted, which represents a percentage of disrupted struts of 0.22%. At 30days, none of our patients died, suffered from stroke, stent thrombosis or needed target lesion revascularization (TLR).
Conclusions: NC balloon HPP of BVS at more than 17atm (up to 20atm) is safe during PCI and allows to achieve better angiographic and clinical results.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijcard.2016.06.029 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!