Background And Purpose: The stiffness of intracranial tumors affects the outcome of tumor removal. We evaluated the stiffness of 4 common intracranial tumors by using MR elastography and tested whether MR elastography had the potential to discriminate firm tumors preoperatively.

Materials And Methods: Thirty-four patients with meningiomas, pituitary adenomas, vestibular schwannomas, and gliomas scheduled for resection were recruited for MR elastography. On the elastogram, the mean and the maximum shear stiffnesses were measured by placing an ROI on the tumor. Blinded to the MR elastography findings, surgeons conducted qualitative intraoperative assessment of tumor consistency by using a 5-point scale. Histopathologic diagnosis was confirmed by using the resected specimens. The mean and maximum shear stiffnesses were compared with histopathologic subtypes, and the intraoperative tumor consistency was graded by the surgeons.

Results: The mean and maximum shear stiffnesses were the following: 1.9 ± 0.8 kPa and 3.4 ± 1.5 kPa for meningiomas, 1.2 ± 0.3 kPa and 1.8 ± 0.5 kPa for pituitary adenomas, 2.0 ± 0.4 kPa and 2.7 ± 0.8 kPa for vestibular schwannomas, and 1.5 ± 0.2 kPa and 2.7 ± 0.8 kPa for gliomas. The mean and maximum shear stiffnesses for meningiomas were higher than those of pituitary adenomas ( < .05). The mean and maximum shear stiffnesses were significantly correlated with the surgeon's qualitative assessment of tumor consistency ( < .05). The maximum shear stiffness for 5 firm tumors was higher than that of nonfirm tumors ( < .05).

Conclusions: MR elastography could evaluate intracranial tumors on the basis of their physical property of shear stiffness. MR elastography may be useful in discriminating firm tumors preoperatively.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7960472PMC
http://dx.doi.org/10.3174/ajnr.A4832DOI Listing

Publication Analysis

Top Keywords

maximum shear
24
shear stiffnesses
20
intracranial tumors
16
kpa kpa
16
shear stiffness
12
firm tumors
12
pituitary adenomas
12
tumor consistency
12
shear
8
stiffness common
8

Similar Publications

Objective: To investigate integrating an artificial intelligence (AI) system into diagnostic breast ultrasound (US) for improved performance.

Materials And Methods: Seventy suspicious breast mass lesions (53 malignant and 17 benign) from seventy women who underwent diagnostic breast US complemented with shear wave elastography, US-guided core needle biopsy and verified histopathology were enrolled. Two radiologists, one with 15 years of experience and the other with one year of experience, evaluated the images for breast imaging-reporting and data system (BI-RADS) scoring.

View Article and Find Full Text PDF

Fabrication of emulsion microparticles to improve the physicochemical stability of vitamin A acetate.

Food Chem

December 2024

Key Laboratory of Geriatric Nutrition and Health (Beijing Technology and Business University), Ministry of Education, School of Food and Health, Beijing Technology and Business University (BTBU), Beijing 100048, China. Electronic address:

Vitamin A is an essential micronutrient crucial for human health, but it is susceptible to degradation when exposed to light, oxygen, and heat, reducing its effectiveness in food production. This study aims to develop vitamin A acetate (VA) emulsion microparticles under an acidic condition using electrostatic complexation and the viscosifying effect to enhance VA physicochemical stability. The stability, encapsulation efficiency (EE), microstructure, and rheological properties of VA emulsion microparticles at different sodium alginate concentrations were investigated.

View Article and Find Full Text PDF

In thermosetting epoxies, thermomechanical properties can be enhanced by conscious selection of curing agents. Full cross-linking leads to a maximum in the glass- transition temperature. However, the relation between the glass transition temperature and the epoxy matrix depends on several factors beyond the cross-linking degree, such as the molecular weight of the polymers, network organization, amount of branching, and the presence of hydrogen bonds.

View Article and Find Full Text PDF

The varied material and the inherent complex microstructure make predicting the effective stiffness of fused deposition modeling (FDM) printed polylactic acid (PLA)/carbon fiber (CF) composite a troublesome problem. This article proposes a microstructure scanning electron microscope (SEM) mapping modeling and numerical mean procedure to calculate the effective stiffness of FDM printing PLA/CF laminates. The printed PLA/CF parts were modeled as a continuum of 3D uniform linear elasticity with orthotropic anisotropy, and their elastic behavior was characterized by orthotropic constitutive relations.

View Article and Find Full Text PDF

Introduction: Up to one in five will suffer from osteoporotic vertebral fracture within their lifetime. Accurate fracture prediction poses challenges using bone mineral density (BMD) measures. Trabecular bone strains may be influenced by the underlying intervertebral disc (IVD).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!