A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Long-Term Contrast Echocardiography and Clinical Follow-Up after Percutaneous Closure of Patent Foramen Ovale Using Two Different Atrial Septal Occluder Devices. | LitMetric

Introduction: Percutaneous patent foramen ovale (PFO) closure by means of a septal occluder device (SOD) is a well-known therapeutic strategy for the secondary prevention of paradoxical embolic neurological events. The aim of this study was to provide long-term echocardiographic and clinical follow-up data on patients who had undergone percutaneous PFO closure with 2 different SOD.

Methods: We selected 2 groups of patients treated with 2 different SOD: Group A: 52 patients with an Amplatzer(®) PFO Occluder and Group B: 49 patients with a Figulla Flex(®) device. All patients underwent follow-up Bubble Test Transthoracic Echocardiography (BTTE) and clinical examination. The results were compared with those recently reported in a group of patients with similar characteristics, but that had been treated conservatively, which acted as a control group.

Results: The mean follow-up after PFO closure was 53 months. The Amplatzer(®) PFO Occluder and the Figulla Flex were used in 52 (51.5%) and 49 (48.5%) of patients, respectively. We found no significant difference in the rate of effective PFO closure between the devices: Amplatzer 91.4%, Figulla 93.9% (P = 0.71). One patient (1.0%) suffered a recurrent neurologic event. BTTE was positive (BTTE+) in 8 patients (8%), 5 with an Amplatzer, and 3 with a Figulla device (P = 0.516). Only 1 patient with BTTE+ had a recurrent TIA (12.5%). No significant relationship was found between device dimensions and BTTE+ (P = 0.062). In the control group (163 patients), the recurrence of neurologic events was 9.2% (15 events), that was significantly higher in respect to the patients who had undergone percutaneous closure of the PFO.

Conclusions: Percutaneous PFO closure was associated with a remarkably low risk of recurrent embolic neurological events, and no long-term device-related major complications. No statistically significant difference emerged between the 2 different SODs regarding BTTE positivity. Long-term follow-up showed that the recurrence of neurological events has been significantly higher in the group treated in a conservative way.

Download full-text PDF

Source
http://dx.doi.org/10.1111/joic.12314DOI Listing

Publication Analysis

Top Keywords

pfo closure
20
neurological events
12
group patients
12
patients
10
clinical follow-up
8
percutaneous closure
8
patent foramen
8
foramen ovale
8
septal occluder
8
embolic neurological
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!