A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Development and Performance Evaluation of a Supermicron Particle Generation System for Aerosol Instrument Calibration]. | LitMetric

Accurate calibration of aerosol measurement instruments is critical for ensuring the data quality when sampling ambient particulate matter (PM) or those from emission sources. A system for calibrating these instruments was set up, which included an ultrasonic device to generate polydisperse supermicron particles, a chamber, and an aerodynamic particle spectrometer to measure particle size distribution. We verified its performance in stably generated testing aerosol with good spatial uniformity, controlled size distributions and concentrations. The testing aerosol generated had a lognormal distribution. A PM₁₀ and PM₂.₅ two-stage virtual impactor was calibrated using this online method. Collection efficiencies of PM₁₀ and PM₂.₅ stages calibrated by an off-line method using monodisperse particles were also used for comparison. The results from two different methods were consistent with each other. Though the off-line method has been widely used to calibrate PM samplers, it suffers from long experimental duration (2-3 days for calibrating one sampler). In contrast, the online method allows for a rapid calibration (less than half a day for calibrating one sampler).

Download full-text PDF

Source

Publication Analysis

Top Keywords

testing aerosol
8
pm₁₀ pm₂₅
8
online method
8
off-line method
8
calibrating sampler
8
[development performance
4
performance evaluation
4
evaluation supermicron
4
supermicron particle
4
particle generation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!