Previous studies have reported a vasoconstrictor response in the radial artery during a cuff-induced low-flow condition, but a similar low-flow condition in the brachial artery results in nonuniform reactivity. This variable reactivity to low-flow influences the subsequent flow-mediated dilatation (FMD) response following cuff-release. However, it is uncertain whether reactivity to low-flow is important in data interpretation in clinical populations and older adults. This study aimed to determine the influence of reactivity to low-flow on the magnitude of brachial artery FMD response in middle-aged and older individuals with diverse cardiovascular risk profiles. Data were analyzed from 165 individuals, divided into increased cardiovascular risk (CVR: n = 115, 85M, 67.0 ± 8.8 years) and healthy control (CTRL: n = 50, 30M, 63.2 ± 7.2 years) groups. Brachial artery diameter and blood velocity data obtained from Doppler ultrasound were used to calculate FMD, reactivity to low-flow and estimated shear rate (SR) using semiautomated edge-detection software. There was a significant association between reactivity to low-flow and FMD in overall (r = 0.261), CTRL (r = 0.410) and CVR (r = 0.189, all P < 0.05) groups. Multivariate regression analysis found that reactivity to low-flow, peak SR, and baseline diameter independently contributed to FMD along with sex, the presence of diabetes, and smoking (total R(2) = 0.450). There was a significant association between reactivity to low-flow and the subsequent FMD response in the overall dataset, and reactivity to low-flow independently contributed to FMD These findings suggest that reactivity to low-flow plays a key role in the subsequent brachial artery FMD response and is important in the interpretation of FMD data.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4923229 | PMC |
http://dx.doi.org/10.14814/phy2.12808 | DOI Listing |
Biomimetics (Basel)
November 2024
Ocean and Maritime Digital Technology Research Division, Korea Research Institute of Ships and Ocean Engineering, Daejeon 34103, Republic of Korea.
Although the Doppler velocity log is widely applied to measure underwater fluid flow, it requires high power and is inappropriate for measuring low flow velocity. This study proposes a fluid flow sensor that utilizes optical flow sensing. The proposed sensor mimics the neuromast of a fish by attaching a phosphor to two pillar structures (A and B) produced using ethylene propylene diene monomer rubber.
View Article and Find Full Text PDFJ Environ Sci (China)
September 2024
Department of Environmental and Prevention Sciences, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy.
Objectives: To examine the role of ferroptosis on the pathogenesis and progression of COVID-19.
Materials And Methods: A total of 127 patients who were hospitalized for COVID-19 were categorized into two groups according to the intensity of oxygen therapy (high-flow or low-flow). Clinical characteristics, laboratory parameters, plasma markers, and peripheral blood mononuclear cell (PBMC) markers were measured at baseline and one or two weeks after treatment.
Zhonghua Jie He He Hu Xi Za Zhi
February 2024
Biomed Rep
November 2023
Institute of Immunology, Faculty of Medicine, Comenius University, 813 72 Bratislava, Slovakia.
Hyperinflammation is one of the most important pathophysiological risk factors for poor prognosis in patients with coronavirus disease-2019 (Covid-19). Low vagal neuro-immune modulation can lead into this kind of immune dysregulation. The association between vagal activity, sex and inflammatory markers were investigated in patients with Covid-19.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!