Purpose: To assess whether contrast-enhanced T1-weighted MR Cholangiography may provide additional information in the evaluation of biliary complications in orthotopic liver transplant recipients.

Material And Methods: Eighty liver transplant patients with suspicion of biliary adverse events underwent MR imaging at 1.5 T scanner. After acquisition of axial T1-/T2-weighted images and conventional T2-weighted MR Cholangiography (image set 1), 3D gradient-echo T1-weighted fat-suppressed LAVA (Liver Acquisition with Volume Acceleration) sequences were obtained about 30 min after intravenous infusion of mangafodipir trisodium (Mn-DPDP,Teslascan(®)) (image set 2). The diagnostic value of mangafodipir trisodium-enhanced MR Cholangiography in the detection of biliary complications was tested by separate analysis results of image set 1 alone and image set 1 and 2 together. MRI results were correlated with direct cholangiography in 46 patients, surgery in 14 and/or clinical-radiological follow-up in the remaining 20 cases.

Results: The level of confidence in the assessment of biliary adverse events was significantly increased by the administration of mangafodipir trisodium (p < 0.05). Particularly, contrast-enhanced T1-weighted LAVA sequences tended to out-perform conventional T2-weighted MR Cholangiography in the delineation of anastomotic and non-anastomotic biliary strictures and in the diagnosis of biliary leak.

Conclusions: Contrast-enhanced T1-weighted MR Cholangiography may improve the level of diagnostic confidence provided by conventional T2-weighted MR Cholangiography in the evaluation of biliary complications after orthotopic liver transplantation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4906040PMC
http://dx.doi.org/10.1016/j.ejro.2016.05.003DOI Listing

Publication Analysis

Top Keywords

image set
16
biliary complications
12
complications orthotopic
8
orthotopic liver
8
cholangiography provide
8
provide additional
8
liver transplant
8
biliary adverse
8
adverse events
8
mangafodipir trisodium
8

Similar Publications

Background: Multifrequency MR elastography (mMRE) enables noninvasive quantification of renal stiffness in patients with chronic kidney disease (CKD). Manual segmentation of the kidneys on mMRE is time-consuming and prone to increased interobserver variability.

Purpose: To evaluate the performance of mMRE combined with automatic segmentation in assessing CKD severity.

View Article and Find Full Text PDF

Introduction: The anterior division of the internal iliac artery (ADIIA) is a crucial vascular structure that supplies blood to the pelvic organs, perineum, and gluteal region. The present study demonstrates practical data concerning the anatomy of the ADIIA and its branches. It is hoped that the results of the current study may aid in localizing the pelvic arteries effectively.

View Article and Find Full Text PDF

A fused-silica three-port grating under TE-polarized normal incidence is designed and manufactured with improved diffraction efficiency (DE) and bandwidth. A physical explanation of the grating diffraction is provided using the simplified mode method (SMM), and parameters of the grating structure were optimized using rigorous coupled-wave analysis (RCWA). For a given set of optimized parameters, a transmitted three-port grating with an area of 170 ×170 was fabricated by scanning beam interference lithography (SBIL), and diffraction properties were investigated.

View Article and Find Full Text PDF

Although second-order surface analyses, mainly mean power and cylinder maps, are commonly used to characterize the progressive addition lens (PAL) surface, recently it has been suggested that third-order variations may also have relevancy in PAL optical and visual performance. This paper proposes a third-order smoothness metric, and its associated Riemannian distance, to further characterize PAL's surface optical performance. These metrics can provide a complementary scoring tool to those classical ones, particularly, to analyze the transition zones between far, near, intermediate, and blending zones.

View Article and Find Full Text PDF

A three-dimensional (3D) waveguide model is applied in extreme ultraviolet (EUV) lithography simulations. The 3D waveguide model is equivalent to rigorous coupled-wave analysis, but fewer field components are used to solve Maxwell's equations. The 3D waveguide model uses two components of vector potential, and , corresponding to the two polarizations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!