Parathyroid 4D-CT: Multi-institutional International Survey of Use and Trends.

Otolaryngol Head Neck Surg

Section of Endocrine Surgery, Department of Surgery, Duke University Medical Center, Durham, North Carolina, USA.

Published: December 2016

Four-dimensional computed tomography (4D-CT) is a new modality for preoperative localization of parathyroid adenomas. We performed a survey study to describe the role and trends in the utilization of 4D-CT. Of 361 radiologists, 200 (55%) reported that 4D-CT was used in their practices. Nineteen (10%) used 4D-CT as the first-line imaging study; 155 (76%) reported that 4D-CT played a secondary role; and 26 (13%) reported that it is performed routinely in combination with ultrasound and scintigraphy. Early adopters of 4D-CT (use for >3 years) were 3 times more likely to use 4D-CT in a first-line role (18%) when compared with radiologists who used 4D-CT for ≤3 years (6%; P < .05). In conclusion, more than half of radiologists perform 4D-CT, and a majority reported that 4D-CT plays a secondary role. However, this role may change, as utilization is increasing and radiologists may follow early adopters, who are more likely to use it as a first-line study.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0194599816655311DOI Listing

Publication Analysis

Top Keywords

reported 4d-ct
12
4d-ct
10
4d-ct first-line
8
secondary role
8
early adopters
8
role
5
parathyroid 4d-ct
4
4d-ct multi-institutional
4
multi-institutional international
4
international survey
4

Similar Publications

Purpose: To use imaging data from stereotactic MR-guided online adaptive radiotherapy (SMART) of ultracentral lung tumors (ULT) for development of a safe non-adaptive approach towards stereotactic body radiotherapy (SBRT) of ULT.

Patients And Methods: Analysis is based on 19 patients with ULT who received SMART (10 × 5.0-5.

View Article and Find Full Text PDF

Objective: The aim of the study is to assess the diagnostic accuracy of 4-dimensional computed tomography (4D-CT) scans for patients with primary hyperparathyroidism (pHPT) after negative or inconclusive Technetium-99m sestamibi single-photon emission computed tomography scan.

Methods: A literature search of several databases was conducted from inception to August 2023. Eligible studies reported adult patients (>18 years old) who underwent 4D-CT after negative or inconclusive sestamibi results.

View Article and Find Full Text PDF

Impact of diaphragm motion on dosimetry in lower thoracic spine stereotactic body radiotherapy.

Phys Med

January 2025

Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.

Background And Purpose: Free-breathing computed tomography (FBCT) used in treatment planning for lower thoracic (Th8-Th12) spine stereotactic body radiotherapy (SBRT) can cause deviations between planned and irradiated doses due to diaphragm movement (DM). This study analyzed the dosimetric impact of DM on lower thoracic spine SBRT.

Materials And Methods: Data were collected from 19 patients who underwent FBCT and four-dimensional CT (4DCT) during the same session.

View Article and Find Full Text PDF

Preclinical Experience Using 4D Intracardiac Echocardiography to Guide Cardiac Electrophysiology Procedures.

J Cardiovasc Electrophysiol

December 2024

Division of Cardiovascular Medicine, Cardiac Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.

Introduction: Intracardiac echocardiography (ICE) is an essential imaging modality for electrophysiology procedures, allowing intraprocedural monitoring, real-time catheter manipulation guidance, and visualization of complex anatomic structures. Four-dimentional (4D) ICE is the next stage in the evolution of the technology, permitting 360° rotation of the imaging plane, simultaneous multiplanar imaging, and volumetric acquisition, similar to transesophageal echocardiography (TEE). In this study, we report our experience with a novel 4D ICE catheter (NuVision, Biosense Webster) in structural electrophysiology procedures and difficult ventricular ablations in a swine preclinical model.

View Article and Find Full Text PDF

Purpose: Motion management presents a significant challenge in thoracic stereotactic ablative radiation therapy (SABR). Currently, a 5.0-mm standard planning target volume (PTV) margin is widely used to ensure adequate dose to the tumor.

View Article and Find Full Text PDF