Overaggressive stent expansion without intravascular imaging: impact on restenosis.

Heart Asia

Department of Cardiology, Princess Alexandra Hospital, Brisbane, Australia; The University of Queensland, Brisbane, Australia.

Published: June 2016

Objective: Aggressive stent expansion is required for optimal strut apposition, but risk of stent deformation, fracture and subsequent restenosis is potentially greater when performed without intravascular imaging guidance. We investigated how frequently stents are 'overexpanded' and whether this correlates with restenosis.

Design And Setting: Single-centre prospective database study at a high-volume tertiary university hospital.

Patients: 243 patients undergoing single-vessel stenting for de novo stenosis in 277 lesions. Exclusion criteria were bifurcational, graft or left main disease and intravascular imaging use. All had ischaemia-driven repeat coronary angiography up to 48 months later. Degree of stent overexpansion was the difference between nominal and final stent size.

Results: Stents were expanded above nominal in 99% of cases and above rated burst pressure in 52%. Stents were expanded >20% above nominal in 12% of cases. Stents overexpanded by >20% were smaller (2.87 vs 3.19 mm), longer (24 vs 19 mm) and more often drug-eluting (53% vs 27%). Angiographic restenosis was observed in 80 lesions (29%). There was no correlation between degree of overexpansion and per cent angiographic restenosis across the whole group (R(2)=-0.01; p=0.09), in those with stent overexpansion >20% (p=0.31) or small stents <3 mm (p=0.71). Indeed, in the group with stent overexpansion >25%, the greater the overexpansion, the less the per cent angiographic restenosis (p=0.02).

Conclusions: In this real-world population undergoing non-complex percutaneous coronary intervention without intravascular imaging, any tendency to overaggressive stent expansion did not predispose at all to restenosis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4832692PMC
http://dx.doi.org/10.1136/heartasia-2013-010430DOI Listing

Publication Analysis

Top Keywords

intravascular imaging
16
stent expansion
12
angiographic restenosis
12
overaggressive stent
8
stent overexpansion
8
stents expanded
8
overexpansion cent
8
cent angiographic
8
restenosis
6
stent
6

Similar Publications

This case report presents the use of intravascular lithotripsy (IVL) in a 68-year-old woman with disabling bilateral claudication owing to a heavily calcified subocclusive stenosis of the infrarenal aorta. The patient had a history of tobacco use, dyslipidemia, and chronic obstructive pulmonary disease, with absent femoral pulses and severe arterial calcification. A 12-mm Shockwave L6 lithotripsy catheter was employed to treat the aortic lesion, resulting in a significant decrease in the aortic pressure gradient without the need for stenting.

View Article and Find Full Text PDF

A dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo Stent (DTS) has been developed to enhance endothelization and capture endothelial progenitor cells; however, vessel responses following DTS implantation remain unclear. Therefore, we evaluated early- and mid-term intravascular characteristics of DTS using intravascular imaging modalities. This multicenter, prospective, observational study enrolled 88 patients (95 lesions) who underwent DTS (43 patients, 48 lesions) or sirolimus-eluting Orsiro stent (SES, 45 patients, 47 lesions) implantation.

View Article and Find Full Text PDF

Risk of acute kidney injury following repeated contrast exposure in trauma patients.

Eur J Trauma Emerg Surg

January 2025

Division of Trauma and Emergency Surgery, Department of Surgery, Chang Gung Memorial Hospital, No. 5, Fuxing St., Guishan Dist., Taoyuan City, 333, Taiwan.

Purpose: This study investigates the risk of contrast-associated acute kidney injury (CA-AKI) in trauma patients, focusing on the impact of cumulative contrast medium doses.

Methods: A retrospective review was conducted at a level 1 trauma center (2019-2021). The study included patients who underwent intravascular contrast-enhanced examinations for torso trauma within 7 days post-injury.

View Article and Find Full Text PDF

The infiltrative and diffuse nature of gliomas makes complete resection unfeasible. Unfortunately, regions of brain parenchyma with residual, infiltrative tumor are protected by the blood-brain barrier (BBB), making systemic chemotherapies, small-molecule inhibitors, and immunotherapies of limited efficacy. Low-frequency focused ultrasound (FUS) in combination with intravascular microbubbles can be used to disrupt the BBB transiently and selectively within the tumor and peritumoral region.

View Article and Find Full Text PDF

Multifunctional Microflowers for Precise Optoacoustic Localization and Intravascular Magnetic Actuation In Vivo.

Adv Healthc Mater

January 2025

Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zürich, Winterthurerstrasse 190, Zurich, 8057, Switzerland.

Efficient drug delivery remains a significant challenge in modern medicine and pharmaceutical research. Micrometer-scale robots have recently emerged as a promising solution to enhance the precision of drug administration through remotely controlled navigation within microvascular networks. Real-time tracking is crucial for accurate guidance and confirmation of target arrival.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!